EarthStone 120-PAGW Instruções de instalação, operação e manutenção - Página 17

Procurar online ou descarregar pdf Instruções de instalação, operação e manutenção para Forno EarthStone 120-PAGW. EarthStone 120-PAGW 18 páginas. Gas fired oven

EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS – ETL LISTED
Please follow the gas requirements listed below:
Inlet Gas Pressure 7" W.C. for Natural Gas - 12"W.C. for LP gas
Manifold Pressure: The amounts listed below are set at the factory.
Natural Gas Manifold pressure
60-PAGW
90-PAGW
110-PAGW
120-PAGW
130-PAGW
160-PAGW
Add 0.5" W.C. for ovens with rear burner.
LP Gas Manifold pressure
60-PAGW
90-PAGW
110-PAGW
120-PAGW
130-PAGW
160-PAGW
The inlet and manifold (outlet) pressure taps are located at the Gas Control Valve. This
part is in the burner controls box and attached to the oven support stand.

GAS PRESSURE

4" W.C.
45,000 btu
4" W.C.
85,000 btu
5" W.C.
110,000 btu
3.5" W.C.
130,000 btu
5" W.C.
140,000 btu
4.5" W.C.
170,000 btu
7"W.C.
45,000 btu
10" W.C.
85,000 btu
10" W.C.
110,000 btu
10" W.C.
130,000 btu
10" W.C.
140,000 btu
10" W.C.
170,000 btu
17