IV. Post-Installation Examination and Troubleshooting
Check by following the steps below after the installation:
1.
Check if there is GSM900 (2G) signal from outside, and if the outdoor antenna's signal is
stable. The outdoor antenna must face either the base station or the signal source. If the
received signal is still weak after the installation, try to adjust the antenna angle of PA400
and check if the indicator of the AMPC1 works normally.
2.
If the strength of the received signal is constant, it means this Kit is functioning properly. A
weak signal means insufficient or saturated AMPC1 that requires some adjustment by
increasing or decreasing the AMPC1. In a situation where the 80% of the indoor signal can
be received, the increase of this Kit will not boost the signal obviously. It will even cause
interference and/or decrease the signal quality. In a situation where only 20% of the indoor
signal is received, a tremendous improvement of signaling quality can be expected by
using this Kit .
V.
Specification of Booster
AMPC1 Specification
Electrical Specifications
Frequency
Bandwidth
P1dB
Input power
Output power
Gain
Noise Figure
Impedance
DC Voltage
DC Current
Mechanical Specifications
Weight (Without Cable)
Size
RF Connector
DC Connector
Label
Housing Material
Environmental Specifications
Working Temperature
Storage Temperature
Note: Specifications subject to change without notice.
http://www.alliscom.com.tw
GSM900 (2G) Booster Kit
Uplink: 890~915MHz
Uplink:25MHz
-40dBm
Absolute Max.
Max.
18dBm
Typ.
Uplink: 40dB, Downlink: 40dB
Max.
10dB
50Ω
DC 5~12V
Absolute Max.
Max.
300mA @ 5V
75 grams max.
79 mm. X 66 mm X 21 mm
Uplink: SMB JACK, Downlink: SMA Jack
Mini USB
ACC Label
ABS
E-mail:
7/10
Downlink: 935~960MHz
Downlink: 25MHz
-5dBm
16V
-30°C< T< +80°C
-40°C< T< +85°C
Tel: 886-2-26952378
Fax: 886-2-26957078
RoHS
Compliant
11/2010