Miele PW 6055 AV Plano de instalações - Página 14
Procurar online ou descarregar pdf Plano de instalações para Máquina de lavar roupa Miele PW 6055 AV. Miele PW 6055 AV 15 páginas. Washing machine
Também para Miele PW 6055 AV: Plano de instalações (11 páginas)
en -
Installation and planning notes
Installation prerequisites
The appliance must be connected only to a system designed in
accordance with national legislation, regulations and directives, as
well as local codes and standards.
In addition, all regulations by utilities, accident prevention regulations,
insurance guidelines and recognized codes of practice valid at the
installation site must be adhered to.
Transport and placement
The washing machine must not be transported without transport
safety. Do not discard the transport safety, because you will have to
reinstall it prior to transporting the washing machine (during a move,
for example).
General conditions of operation
Ambient temperature of the installation space: +35°F (2°C) to +95°
(35°C).
Depending on the properties of the installation site, noise and/or
vibrations may be transmitted into the building. It is recommended to
have a noise protection expert examine the appliance's installation
site when more stringent demands on sound insulation are made.
Electrical connection
Depending on the design, the appliance may be fitted with a
connection cable with or without a plug.
The appliance must be connected only to an electric supply designed
in accordance with national and local regulations. The installation
must be performed by a qualified electrician.
The appliance data plate indicates the nominal power consumption
and the appropriate fuse capacity. Compare the specifications on the
data plate with those of the electrical power supply.
The appliance can be connected either via a permanent connection or
a plug-in connection. However, we recommend connecting the
appliance via a plug connection so that an electrical safety check can
be carried out, e.g. during repair or maintenance.
If a permanent connection is intended, an all-pole disconnection
device must be provided at the installation side. Disconnect devices
may be switches with a contact gap of more than 3 mm, such as
MCBs, fuses and guards.
The plug-in connection or disconnect device must be accessible at all
times. You must be able to lock the separator or monitor it at all times
in case the appliance has to be disconnected from the power supply.
Only a certified or approved electrician may perform the initial
installation of the connection, change the system or inspect the
ground conductor, including a determination of the correct protection,
because they are familiar with the relevant regulations and the
particular requirements by the electrical utility.
Comply with the switch-over instructions on the wiring diagram
when switching the appliance to a different voltage. Only
authorized distributors or Miele customer service representatives
may convert the appliance. In this event, it is also necessary to
adjust the heat output.
Devices for an automatic shut-down of the appliance (such as timers)
must not be installed.
The conductor cross-section information in the technical data refers
only to the required connecting cable. Refer to the applicable national
and local regulations for calculating the other dimensions.
Cold water connection
You may connect the washing machine to a drinking water system
without a backflow preventer because it has been designed according
to the applicable standards for drinking water protection.
For the connection, you require a water shut-off valve or a tap with
connecting thread. If such is missing, only an authorized plumber may
connect the appliance to the drinking water pipe.
A suitable connection hose with screw fitting is supplied with the
appliance.
Authorized Miele distributors and Miele Customer Service
representatives can provide you with hoses of 8' 2 ½" or 13' 1 ½" (2.5
or 4 m) length to extend the hose.
14
Hot water connection
The connection conditions for the hot water connection to up to 158°F
(70°C) are the same as those for the cold water connection.
A suitable connection hose with screw fitting is supplied with the
appliance.
The appliance may be connected to a hot water system from 158°
(70°C) to 185° (85°C) max., however, you will require a special heat-
resistant inlet hose.
Purchase this inlet hose from a Miele authorized distributor or Miele
Customer Service. In addition, the appliance must be programmed
correspondingly by Miele Technical Service or an authorized dealer.
For functional reasons, it is not possible to connect the appliance
to a hot water supply only.
If the building does not have a hot water supply, the hot water
connection must be connected to an existing cold water supply.
Alternatively, close the hot water connection with the supplied dummy
cap and convert the appliance controller to colt water inlet.
In this event, you must add the water demand for hot water to the cold
water demand.
Service water connection
The service water connection can be optionally retrofitted using an
additional kit.
The same connection conditions as for the cold water connection
apply.
Drain valve (depending on device variant)
The washer is drained with a motorized drain valve. Use an off-the-
shelf elbow connector to connect directly to the building's waste water
system (without syphon) or into a floor drainage (catch pit with air
trap).
For a fault-free drainage, you must use a vented pipe layout. If the
available ventilation is insufficient, you may purchase a ventilation
assembly kit (Mat. No. 05 239 540) from an authorized Miele
distributor or Miele Customer Service.
Ensure sufficient dimensions for the simultaneous operation of all
devices if you connect several appliances to a collecting pipe.
Soap water pump (depending on device variant)
The appliance drains through a pump with a 1 m delivery head. For
the water to drain freely, the hose must be free of kinks. The elbow at
the hose end can be rotated and removed, if necessary.
Water drain options:
1. Direct connection to a plastic pipe with rubber sleeve (syphon not
mandatory).
2. Attach to a sink with a plastic fitting.
PW 6055/6065
10 145 220 / 01