Miele PW 6101 Manual de instruções de programação - Página 32
Procurar online ou descarregar pdf Manual de instruções de programação para Máquina de lavar roupa Miele PW 6101. Miele PW 6101 48 páginas. Profitronic m innovation m
Também para Miele PW 6101: Manual de Instruções (44 páginas), Manual de Instruções (46 páginas), Manual de instruções de programação (48 páginas)
Settings
Dispensing correction factor (D1 to D 13)
The correction factor can be used when
changing from one liquid agent to another. If,
for example, the agent used in dispenser
pump D 1 is changed (to one with a higher
concentration level), the correction factor
can be used to reset the pump quickly.
To calculate the factor:
Correction factor D1 =
Current amount Dos-p. D1
Supervisor level ~ Settings
Dispensing correction factor
Dispenser level reminder
After selecting "Dispensing correction factor"
Settings ~ Dispensing correction factor
Dispenser pump 1: 1,00
Dispenser pump 2: 1,00
Selection choice: - 2
- 1,99 to 0,01
After coming out of supervisor level the new
dispensing amounts will be used although
the programming has not been changed.
Dispenser level reminder (D 1 to D 13)
If you want to be reminded when a
dispenser is low the relevant dispensers
need to be programmed.
Supervisor level ~ Settings
Dispenser level reminder
Password required: Yes
After selecting "Dispenser level reminder"
Settings ~ Dispenser level reminder
Dispenser pump 1: Yes
Dispenser pump 2: Yes
Selection choice: - Yes - No
32
New amount Dos-p. D1
-
e
A
e
A
-
e
A
e
A
Password required
You deselect the password requirement
here.
Selection choice: - Yes - No
Please be aware that if a password is
currently required and you change this
setting to "No" the user will be asked to enter
the current password after pressing the
A button.
Medium water pressure
The machine must be set for a medium
water pressure for calculating consumption
data. This setting is also used for calculating
the amount of water used in the individual
blocks and for a complete programme.
Selection choice: - 0.1 to 50 bar
- 1 to 800 psi
Heater voltage
The heater voltage is required for calculating
the heater rating.
Selection choice: - 500 to 0 V
M.-Nr. 06 533 430