5.2 Advanced settings of the stroke (parameter LsI
Be sure that the limit switches are connected and correctly adjusted
In this procedure is necessary to provide the positions of beginning of slowing down with a step by step command (SS).
Unlock the gate and move it to the middle of the stroke
1
Press and keep pressed the buttons UP[+] e MENU
for at least 5 seconds.
2
When the gate reaches the opening limit switch it
3
stops by itself
When the gate reaches the position of beginning of
4
slowing down give a step by step command (SS)
When the gate reaches the closing limit switch it stops
5
by itself
When the gate reaches the position of beginning of
6
slowing down give a step by step command (SS)
When the gate reaches the opening limit switch it
7
stops by itself
Warning: in case of intervention of a safety device, the learning is stopped and will appear on the display the written
Press Step by Step button to start again the learning from the 2
6-1622241
rev.6
04/12/2018
LsI = P P P P )
LsI
LsI
The gate moves in opening.
If the gate moves in closing press the button
DOWN to stop and reverse the direction of
movement and give a step by step command
(SS) to resume the procedure
The gate moves in closing
The gate begins the slowing down
The gate moves in opening
The gate begins the slowing down
The gate closes with the settings of slowing down
set in this learning. When the gate is closed the
learning phase is ended.
nd
point.