9. Adjusting of the motors velocity in slowing down
This procedure must ONLY be carried out by the installer and ONLY during the put in function of the system. For a correct programming, before
carrying out any modification, bring always back the door to the totally closed position.
With the door in movement check
the velocity of the door in slowing
down phase.
WARNING: it is indispensable to carry out, after adjusting the desired velocity in slowing down, a new programming of the strokes in
WARNING: The adjustments must be carried out so that it is possible to declare the conformity according to the Machine
Directive 98\37\CE and particularly to the EN 12445; EN 12453 ed EN 12635 regulation and successive modifications.
10. Adjusting of the automatic reclosure time
This procedure must ONLY be carried out by the installer and ONLY during the setting up of the system. For a correct
programming, before any modification, bring always the gate back to the totally closed position.
With the gate closed give a
step by step command and
wait for complete opening.
Disabling of the automatic re - closing
Turn the trimmer A. RE-CLOSURE TIME completely in clockwise
sense. In this way the automatic reclosure is disabled.
Immediate reclosing by photocells
Rotate the AUTOMATIC RECLOSING trimmer completely anticlockwise
to enable the immediate reclosing by photocells. If the beam of the
photocell's will be interrupted during openinng or when the completely
open position is reached the automation will recloses immediately, when
opening position is reached. If the beam won't be interrupted the control
unit recloses after 30 seconds.
6-1622381
rev.2
04/02/2016
It is possible to turn the SLOW DOWN
VELOCITY trimmer in clockwise sense to
increase the velocity of the motors.
The velocity is too low
The velocity is too high
It is possible to turn the SLOW DOWN
VELOCITY trimmer in anti clockwise sense to
lower the velocity.
the case in which the slowing down phase is personalized.
Turn the trimmer A. RE-CLOSURE TIME in clockwise sense. In this
way the automatic reclosure time increases.
Maximum time settable 3 minutes.
The Automatic re-closure
time is too short
The Automatic re-closure
time is too long
Turn the trimmer A. RE-CLOSURE TIME in anti-clockwise sense. In
this way the automatic reclosure time decreases.
Minimun time settable 3 seconds.
ITA
ENG
FRA
AUTOMATIC
RECLOSING
AUTOMATIC
RECLOSING
ESP
DEU
POR
SLOW.DOWN.
VELOCITY
SLOW.DOWN.
VELOCITY
AUTOMATIC
RECLOSING
AUTOMATIC
RECLOSING