Miele 09 968 240 Instruções de utilização e de instalação - Página 32
Procurar online ou descarregar pdf Instruções de utilização e de instalação para Campânula de ventilação Miele 09 968 240. Miele 09 968 240 40 páginas.
Exhaust duct
Condensate trap
In addition to insulating the exhaust
duct, we recommend installing a
condensate trap to collect and
evaporate any condensate which might
accumulate.
Condensate traps are available for
exhaust ducts with a diameter of 5"
(125 mm) or 6" (150 mm).
When installing a condensate trap,
make sure that it is positioned
vertically and, if possible, directly
above the hood outlet duct collar.
The arrow on the housing indicates
the direction of airflow.
32
Reducing Collar
(optional accessory)
If you would like to reduce the
environmental impact of your ventilation
system by limiting the CFM output the
Reducing Collar can be installed. It
reduces the air flow to less than 400
CFM. Check local building codes for
max. CFM requirements.
Push the Reducing Collar on the
exhaust port of the fan.
Push the exhaust hose over it.
Fix both with a hose clamp.