Miele DA 429-4 Manual de operação e instalação - Página 12

Procurar online ou descarregar pdf Manual de operação e instalação para Campânula de ventilação Miele DA 429-4. Miele DA 429-4 40 páginas. Cooker
Também para Miele DA 429-4: Manual de operação e instalação (40 páginas), Instruções de utilização e de instalação (40 páginas)

Miele DA 429-4 Manual de operação e instalação

Description of the functions

The rangehood works with
. . . air extraction:
The air is drawn in and cleaned by the
grease filters and directed outside.
If the on-site ventilation system does
not have a non-return flap, the
non-return flap supplied with the
appliance must be fitted in the exhaust
socket in the motor unit.
Having a non-return flap fitted in the
ducting ensures that air, once ducted
to the outside, cannot get back into the
room again.
The flap is closed when the rangehood
is switched off.
When the rangehood is switched on,
the non-return flap opens for the
cooking vapours to be blown directly
outside.
Please note, the performance of
this rangehood hinges greatly on
the installed ducting to vent the
vapours. Poor choice of ducting
results in poor rangehood
performance. For ducting
recommendations, please refer to
the relevant section in these
operating instructions or contact a
specialised installer.
12
. . . air recirculation:
(available as an optional extra with a
conversion kit and charcoal filter: see
"Technical Data")
The air is drawn in and cleaned first by
the grease filter and then by a charcoal
filter. The cleaned air is then
recirculated back into the kitchen
through grilles in the top of the
rangehood extension piece.
Before using the rangehood in
recirculation mode, ensure that the
charcoal filter is in place. See
"Cleaning and care".
. . . an external motor:
(Models ...EXT)
The EXT models are designed to be
connected to an external motor located
outside the room.
The external motor is connected to the
rangehood by means of a control cable,
and is operated by the controls on the
rangehood.