Miele DAR 1225 Instruções de utilização e de instalação - Página 29
Procurar online ou descarregar pdf Instruções de utilização e de instalação para Campânula de ventilação Miele DAR 1225. Miele DAR 1225 40 páginas.
Safety distance between hob and cooker hood (S)
When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance
Electric hob
Electric grill, deep fat fryer (electric)
Multi-burner gas hob,
total output ≤ 12.6 kW, no burner > 4.5 kW
Multi-burner gas hob,
total output > 12.6 kW and ≤ 21.6 kW,
no burner > 4.8 kW.
Multi-burner gas hob,
total output > 21.6 kW,
or multi-burner gas hob where one burner > 4.8 kW.
Single burner gas hob, output ≤ 6 kW.
Single burner gas hob, output > 6 kW and ≤ 8.1 kW.
Single burner gas hob, output > 8.1 kW
Installation
Minimum distance S
450 mm
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible
29