PT 5135/7135
Technical data
Standard voltage (FIN only)
Frequency
Total rated load
Fuse rating (B trip rating according to EN 60898)
Supply lead min. cross-section
Supply lead without plug for hard-wired connection
Length of supply lead
Alternative voltage (convertible)
Frequency
Total rated load
Fuse rating (B trip rating according to EN 60898)
Supply lead min. cross-section
Alternative voltage (convertible)
Frequency
Total rated load
Fuse rating (B trip rating according to EN 60898)
Supply lead min. cross-section
Standard voltage (AUS only)
Frequency
Total rated load
Fuse rating
Supply lead min. cross-section
Supply lead with plug
Length of supply lead
Standard voltage (J only)
Frequency
Total rated load
Fuse rating
Supply lead min. cross-section
Supply lead with plug
Length of supply lead
C o n d e n s a t e d r a i n h o s e ( AS K )
Drainage temperature, max.
Max. transient flow rate
On-site hose sleeve for drain hose (outer dia. x length)
Drain hose (internal diameter)
Drain hose length
Drain pump head height from bottom edge of machine, max.
C o o l i n g a i r i n t a k e ( K L Z )
Air flow must remain unobstructed at all times
C o o l i n g a i r d i s c h a r g e v e n t ( K L A)
Air flow must remain unobstructed at all times
E q u i p o t e n t i a l b o n d i n g ( P A)
Machine connection (separate kit required)
P e a k l o a d / e n e r g y m a n a g e m e n t ( S L A )
Machine connection (separate kit required)
Control signal voltage
P a ym e n t s ys t e m c o n n e c t i o n ( K G A )
Connection of payment systems
C o m m u n i c a t i o n m o d u l e ( X K M )
RS 232 serial interface (XKM module retrofitting kit)
= standard, = optional, + = only on request, - not available
10 145 320 / 01
PT 5135 C
PT 7135 C
-
2N AC 400 V
Hz
-
50
kW
-
3.68
A
-
2 x 10
mm²
-
4 x 1.5
-
mm
-
2000
1N AC 230 V
Hz
-
50
kW
-
3.68
A
-
1 x 16
mm²
-
3 x 1.5
1N AC 230 V
Hz
-
50
kW
-
2.17
A
-
1 x 10
mm²
-
3 x 1.5
-
1N AC 230-240 V
Hz
-
50
2.17 – 2.34
kW
-
A
-
1 x 10
mm²
-
3 x 1.0
-
mm
-
2000
-
1N AC 200 V
50 – 60
Hz
-
kW
-
3.7
A
-
1 x 20
mm²
-
3 x 2.75
-
mm
-
2000
°C
70
70
l/min
3.6
3.6
mm
10 x 30
10 x 30
mm
10 (DN10)
10 (DN10)
mm
1800
1800
mm
1000
1000
230 V
230 V
en - GB