Table II
Effective duct
length (yds)
0 - 13
12 - 25
25 - 45
Flexible metal ducting has been used
for the following example.
INSTALLATION INSTRUCTIONS
Internal diameter or
edge length (inches)
4''
5''
6''
Example:
Exhaust connection, left . . . . . . . . 193''
Length (L) . . . . . . . . . . . . . . . . . . . . 46''
Lower radius (R=4'') . . . . . . . . . . . . 20''
Height (H) . . . . . . . . . . . . . . . . . . . . 46''
Upper radius (R=2'') . . . . . . . . . . . . 20''
Wall pipe with louvred vent . . . . . . 142''
Effective duct length . . . . . . . . . . . 467''
. . . . . . . . . . . . . . . . . . 467'' = 12.9 yds
Result:
A duct diameter of 4'' is adequate
since the effective length is less than
13 yd as specified in Table II.
23