The height of the plinth facing has to
be altered in the following
circumtances:
If the building-under height A = 820
mm and the plinth facing height b is
greater than 100 mm a cut-out has to
be made in the plinth facing.
This also applies to a building-under
height A = 870 mm and plinth facing
height b greater than 150 mm.
Building-under
height A [mm]
820
870
Dimension H
[mm]
100
150
Installing the appliance
^ Position the plinth facing along the
run of kitchen units a.
^ Mark the protruding section A on the
ventilation grille bracket a with a
pencil, then take the plinth facing b
off again.
^ Cut protruding section A off the
ventilation grille.
29