Warranty

This warranty covers all parts with material or manufacturing defects for two
(2) years from date of purchase. The buyer's only remedy is the replacement
or repair of the defective parts. In no case can labor costs and any
consequential damage be cited as a basis for a complaint. Any returned units
must be complete and must be accompanied by a written list of the defects
identified. We are unable to accept any liability in case of nonconforming
installation or noncompliance with the specifications or maintenance
recommendations.

Maintenance

● This pump like all mechanical equipment requires maintenance.
● Clean the filter and reservoir thoroughly every 6 months using an
anti-bacterial wash. Take care not to damage the signal pins on the
reservoir cover.

Faults and Troubleshooting

Problem
Cause
Pump runs all the
1. Reservoir is not leveled.
2. Reservoir is dirty.
time
Pump stops and
The water is siphoning back
starts and makes a
through the pump
loud noise
There are air-leaks in the pipe
Pump runs but does
not pump any water
running to the pump.
Pump does not
No power supply.
operate
Incorrect or damaged cable.
Incorrect voltage.
-07-
Action
1. Check reservoir to ensure it is installed flat-
side down and on a level horizontal surface.
2. Clean the reservoir and the surface of the
signal pins.
Remove air from the tube between the
reservoir and the pump after installation and
during operation.
Check the reservoir and section tube are
free of sludge and debris.
Check the power supply.
Check the power cable.
Check the voltage.
NOTE:
-08-