ALLO STM Manual de instalação rápida - Página 8

Procurar online ou descarregar pdf Manual de instalação rápida para Firewall ALLO STM. ALLO STM 11 páginas. Sip threat manager
Também para ALLO STM: Manual de instalação rápida (9 páginas)

STM Quick Installation Guide
STM Appliance 1
The device operates as a transparent bridging firewall with Deep Packet Inspection enabled on
the SIP traffic. By default, the appliance has been configured with static IP of 10.0.0.1 (Net mask
255.255.255.0).
The device has been made to be fully functional with the default configuration. However if the
user needs to tune the device settings & the DPI policies, they can tune the configuration via the
Device WebUI.
The device also provides the command line interface accessible via SSH, which will allow
configuring the basic settings and viewing device status.
Management Access
Web GUI
SSH CLI
Management Vlan IP
Default Device IP

4. Accessing the WebUI

The user can connect to the device via management Vlan to access WebUI during initial setup.
The management Vlan configured on the device, is accessible via the LAN/WAN ports & is made
assigned to the default IP address '192.168.100.1'
Use the procedure given below to access the WebUI,
1. Connect the LAN port of the STM to a PC.
2. Assign the IP Address 192.168.100.2 to the PC. Set the Net mask as 255.255.255.0.
Now you can access the device from the browser using the URL
Configure the STM Device IP Address from the "Device Settings" Page as per your local network
range. Verify the IP address set to STM from the dashboard page. Once the user assigns the STM
Device IP Address successfully, he can access the device using that IP address further.
www.allo.com
Login Credentials
admin/admin
admin/stmadmin
192.168.100.1/255.255.255.0
10.0.0.1/255.255.255.0
https://<192.168.100.1>
Version 2.0
8