Burkert 2031 Manual de início rápido - Página 8
Procurar online ou descarregar pdf Manual de início rápido para Controlador Burkert 2031. Burkert 2031 12 páginas. Inox 2/2-way diaphragm valve
Também para Burkert 2031: Manual de início rápido (19 páginas)
![Burkert 2031 Manual de início rápido](/uploads/products/server2/352118/352118.jpg)
devices with Vg/Vs welded body
Before welding the body, the actuator must be removed.
6.2
Installation
WarnIng!
risk of injury from incorrect installation!
Non-observance of the specified tightening torque is hazardous
as the device may be damaged.
▶ Observe tightening torque during installation.
6.2.1
Devices with VG/Vs welded body
Before welding the body, the actuator must be removed.
Remove actuator and diaphragm from the body
procedure for control function a:
→
Apply control air connection with compressed air (5.5 bar).
→
Loosen fastening screws in diagonal pairs and remove actuator
together with diaphragm from the body.
→
Weld body into the pipeline.
procedure for control function B:
→
Loosen fastening screws in diagonal pairs and remove actuator
together with diaphragm from the body.
→
Weld body into the pipeline.
8
english
Type 2031 INOX
Installation
6.2.2
Installation
installation for actuator with control function a:
→
Align diaphragm.
the mark tab of the diaphragm must be vertical to the flow
of direction.
→
Place actuator on the body.
→
Apply control air connection with compressed air (5.5 bar).
→
Lightly tighten fastening screws crosswise until the diaphragm is
situated between the body and actuator.
do not tighten screws yet!
→
Switch diaphragm valve twice.
→
Tighten fastening screws.
Observe tightening torque (2.5 Nm)!
installation for actuator with control function B:
→
Align diaphragm.
the mark tab of the diaphragm must be vertical to the flow
of direction.
→
Place actuator on the body.
→
Lightly tighten fastening screws crosswise until the diaphragm is
situated between the body and actuator.
do not tighten screws yet!
→
Apply control air connection with compressed air (5.5 bar).
→
Switch diaphragm valve twice.
→
Tighten fastening screws.