My Unit is Cutting Out
1. For optimum function of the unit, we highly recommend the pump is
positioned on a brick, so it is not resting directly on the bottom on the pond.
This is to prevent large clumps of debris blocking the inlets and restricting the
flow.
2. Ensure that all O-rings are in place and well lubricated.
3. Locate the impeller and shaft in the pump and inspect for damage and clear
the fittings and parts of any waste build-up.
4. Ensure that the plastic propeller part of the impeller is attached to the
magnetic part and that they have not come apart or split. If these parts looks
fine and there are two rubber grommets fitted on each end of the shaft, or
already inside the fittings, then re-assemble the unit.
If none of the above resolves your issue, or you require spare parts for your
pump, please contact the supplier of your unit.
MODEL:
MAX HEIGHT (cm)
MAX FLOW RATE:
DIMENSIONS (LxWxH) (mm):
OUTLET FITS:
WATTAGE:
CABLE LENGTH:
VOLTAGE:
MODEL:
MAX HEIGHT (cm)
MAX FLOW RATE:
DIMENSIONS (LxWxH) (mm):
OUTLET FITS:
WATTAGE:
CABLE LENGTH:
VOLTAGE:

SPECIFICATIONS

FPP-600
130
600 L/H
105 x 66 x 475
12 & 16mm FLEXIBLE HOSE
8w
10m (Plug not included)
220-240V
FPP-2000
200
2000 L/H
160 x 90 x 615
20 & 25mm FLEXIBLE HOSE
35w
10m (Plug not included)
220-240V
FPP-900
150
900 L/H
150 x 77 x 485
12 & 16mm FLEXIBLE HOSE
20w
10m (Plug not included)
220-240V
FPP-3000
300
3000 L/H
180 x 100 x 620
20 & 25mm FLEXIBLE HOSE
55w
10m (Plug not included)
220-240V
FPP-1500
180
1500 L/H
150 x 85 x 490
12, 16 & 20mm FLEXIBLE HOSE
25w
10m (Plug not included)
220-240V