Miller Auto Arc 160 Manual do Proprietário - Página 15

Procurar online ou descarregar pdf Manual do Proprietário para Sistema de soldadura Miller Auto Arc 160. Miller Auto Arc 160 41 páginas.

Miller Auto Arc 160 Manual do Proprietário
3-4. Electrical Service Guide
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC)

3-5. Selecting A Location And Connecting Input Power

18 in (457 mm) of
space for airflow
Y Always connect
grounding
conductor first.
= GND/PE
1
Y Do not move or operate unit
where it could tip.
4
L1
L2
2
1
Rating Label
Supply correct input power.
2
Plug
3
Receptacle
Connect plug to receptacle.
4
Line Disconnect Device
See Section 3-4.
Y Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
3
L1
L2
230 VAC, 1
ssb2.2* 1/94 − ST-802 015
OM-187 924 Page 13
230
19.4
30
14
66 (20)
14
S-0092-J