2-10. Inductance Selection

Tools Needed:
3/8, 7/16 in
3/8 in
Weld Bead Using The Tap Stabilizer
Connection With 17 Volts, 100 Amps

2-11. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose – no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
OM-1317 Page 14
2
5
4
6
1
2
Time-Delay
Normal Operating 3
1
3
7
Weld Bead Using The End Stabilizer
Connection With 17 Volts, 100 Amps
Remove left side panel.
1
Stabilizer Z
Tapped stabilizer Z is factory con-
nected to the stabilizer tap which
suits most GMAW applications.
Stabilizer Z controls the inductance
applied to the weld current. To in-
crease inductance and wet out the
weld puddle, connect to stabilizer Z
ending.
To change inductance proceed as
follows:
2
Lead 24
3
Stabilizer Z Tap
4
Stabilizer Z Ending
5
Lead 25
To decrease inductance, connect
lead 25 to stabilizer tap and secure.
Reinstall side panel.
6
Typical Weld Bead Using The
Tap Stabilizer Connection
Use the tap Stabilizer connection
when welding with 100% CO
shielding gas.
Use either stabilizer connection,
depending upon your arc prefer-
ence, while welding with a mixed
shielding gas.
Use stabilizer Z ending to weld on
stainless steel.
7
Typical Weld Bead Using The
End High Stabilizer
Connection
Use the end Stabilizer connection
to reduce weld bead crowning, and
spread the weld puddle.
Install left side panel.
Ref. ST-148 265-B / Ref. ST-801 379-B
200
230
460
54
47
23.5
60
50
25
80
70
35
8
8
12
109
144
236
(33)
(44)
(72)
8
8
12
2