Miller Cool Runner 3CS Manual do Proprietário - Página 11
Procurar online ou descarregar pdf Manual do Proprietário para Sistema de soldadura Miller Cool Runner 3CS. Miller Cool Runner 3CS 24 páginas.
Também para Miller Cool Runner 3CS: Manual do Proprietário (20 páginas)
4-1. Serial Number And Rating Label Location
The serial number and rating information for this product is located on the front. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
4-2. Specifications
.
The correction factor on the cooling power at an ambient temperature of 1045F (405C) is 0.625.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns
Use With Guns/Torches Rated Up To 400 Amperes
Coolant Tank Capacity
Dimensions (Length x Width x Height)
Weight
Input Voltage
Input Amperage
4-3. Coolant Specifications
Do not use conductive coolant.
Application
GTAW Or Where High Frequency Current Is Used
GMAW Or Where High Frequency Current Is Not Used
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -37
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).
4-4. Environmental Specifications
A. IP Rating
B. Temperature Specifications
Operating Temperature Range
14 to 104 °F (-10 to 40°C)
SECTION 4 − SPECIFICATIONS
3 gal (11.4 L) Coolant Tank Capacity; Flow Rate Is 1 Liter Per Minute (1.1 Quarts)
Cooling Unit Dimensions: 25-5/8 in (651 mm) Long, 19-13/16 in (503 mm) Wide, 10-3/4 in (273 mm) High;
Base Dimensions: 25-15/16 in. (659 mm) Long, 22-1/4 in. (565 mm) Wide, 11-15/16 in. (659 mm) High
40 lb (18Kg)
115 VAC, Single Phase, 50 or 60 Hz
5.9 A 60 Hz
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 32
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 32
Aluminum Protecting Coolant 043809*
°
°
F (-38
C) and resist algae growth.
This equipment is designed for outdoor use.
Coolant
IP Rating
IP23
Storage/Transportation Temperature Range
−4 to 131°F (−20 to 55°C)
°
°
F (0
C)
°
°
F (0
C)
IP23 2017−02
Temp1_2016- 08
OM-230161 Page 7