Miller CST 280 VRD International Manual do Proprietário - Página 26

Procurar online ou descarregar pdf Manual do Proprietário para Sistema de soldadura Miller CST 280 VRD International. Miller CST 280 VRD International 48 páginas. Arc welding power source

Miller CST 280 VRD International Manual do Proprietário

3-15. Connecting 3-Phase Input Power

4
3
6
Tools Needed:
OM-217 655 Page 22
3
7
1
= GND/PE Earth Ground
2
L1
5
L2
L3
Y Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.
Y Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit.
Y Always connect green or green/
yellow
conductor
to
grounding terminal first, and never
to a line terminal.
See rating label on unit and check input
voltage available at site.
1
Input Power Cord.
2
Disconnect Device (switch shown in
the OFF position)
3
Green Or Green/Yellow Grounding
Conductor
4
Disconnect Device Grounding
Terminal
5
Input Conductors (L1, L2 And L3)
6
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1, L2, and L3
to disconnect device line terminals.
7
Over-Current Protection
Select type and size of over-current
protection using Section 3-11 (fused dis-
connect switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.
803 766-A / 803 942-A
supply