Miller CST 282 Manual do Proprietário - Página 20

Procurar online ou descarregar pdf Manual do Proprietário para Sistema de soldadura Miller CST 282. Miller CST 282 42 páginas.

Miller CST 282 Manual do Proprietário
5-2.

Weld Output Terminals And Selecting Cable Sizes

NOTICE – The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source
is 100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine
cable size.
100 ft (30 m) or Less
10 - 60%
Welding
Duty Cycle
Amperes
AWG (mm
2
)
100
4 (20)
150
3 (30)
200
3 (30)
250
2 (35)
300
1 (50)
350
1/0 (60)
* This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm
2
for metric use.
***For distances longer than those shown in this guide, see AWS Fact Sheet No. 39, Welding Cables, available from the American Welding
Society at http://www.aws.org.
5-3.

Remote 14 Receptacle Information

A
J
K
I
B
C L N
H
M
D
G
F
E
*The remaining sockets are not used
OM-285986 Page 14
Complete Parts List is available at www.MillerWelds.com
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit Not Exceeding***
150 ft (45 m)
60 - 100%
Duty Cycle
AWG (mm
2
)
4 (20)
4 (20)
3 (30)
2 (35)
2 (35)
1 (50)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
2/0 (70)
3/0 (95)
Remote 14
14 Volts DC Output
Contactor
Remote Output
Control
803 942-A
200 ft (60 m)
250 ft (70 m)
10 - 100% Duty Cycle AWG (mm
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
2/0 (70)
3/0 (95)
3/0 (95)
4/0 (120)
4/0 (120)
2x2/0 (2x70)
Socket
A
14 volts DC. Circuit Limited to 35mA
Contact closure to A completes contactor con-
B
trol circuit.
Output to remote control; +10 volts DC output to
C
remote control.
D
Remote control circuit common.
0 to +10 volts DC input command signal from re-
E
mote control.
350 ft
300 ft (90 m)
(105 m)
2
)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
4/0 (120)
4/0 (120)
2x2/0 (2x70)
2x2/0 (2x70)
2x3/0 (2x95)
2x3/0 (2x95)
2x3/0 (2x95)
Socket Information
400 ft
(120 m)
1/0 (60)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x4/0
(2x120)