Miller XMT 456 CC/CV Manual do Proprietário - Página 27

Procurar online ou descarregar pdf Manual do Proprietário para Sistema de soldadura Miller XMT 456 CC/CV. Miller XMT 456 CC/CV 40 páginas.

Miller XMT 456 CC/CV Manual do Proprietário
5-4. Removing Right Side Panel and Measuring Input Capacitor Voltage in 575 Volt
Models
Tools Needed:
5/16 in
Y Significant DC voltage can remain on capacitors af-
ter unit is Off. Always check the voltage as shown
to be sure the input capacitors have discharged be-
fore working on unit.
2
3
+ lead to lower right
terminal, − lead to
upper right terminal
1
Turn Off welding power source, and
disconnect input power.
1
Right Side Panel
To remove panel, remove screws
securing panel to unit.
2
Interconnect Board PC2
3
Voltmeter
Measure the dc voltage across the
screw terminals on PC2 as shown
until voltage drops to near 0 (zero)
volts.
Proceed with job inside unit. Rein-
stall right side panel when finished.
Ref. ST-801 718 / Ref. ST-801 536-A
OM-2232 Page 23