7-1. Setup Menu
To enter the SETUP MENU press and re-
lease the SETUP button. The SETUP
MENU INDICATOR and the SETUP
BUTTON INDICATOR will illuminate.
Rotate the LEFT ADJUST KNOB to select
different menu items shown in the LEFT
DISPLAY. Rotate the RIGHT ADJUST
KNOB to change menu item values shown
in the RIGHT DISPLAY.
To exit the SETUP MENU press and re-
lease the SETUP button.
Items that can be adjusted in this menu are:
Trigger Control (TRIG) − Sets the gun
trigger control. The trigger control can be
configured as (2T, HOLD, 4T, SPOT). See
Section 6-2.
Trigger Hold Delay (HOLD) − Additional
trigger setting only appearing in the menu
Notes
SECTION 7 − PROGRAMMING
when the trigger control is set to (TRIG
HOLD). Trigger hold delay time is the min-
imum amount of time the trigger must be
held for trigger hold to become active.
There is a built in maximum trigger hold
time which the trigger must be released
within for trigger hold to become active.
The maximum trigger hold time is always
4.0 seconds after the trigger hold delay
time. For Example, if the trigger hold delay
time is set to 2.0 seconds, the trigger must
be held for at least 2.0 seconds and re-
leased within 6.0 seconds for trigger hold to
become active. Once the trigger hold func-
tion is active, the wire feeder will continue
feeding wire until the trigger is pressed and
released again.
Preflow (PRE) − The amount of time that
the shielding gas will flow after the trigger
is pressed and before the welding arc will
be allowed to be active. Range of this set-
ting is from (0.0 to 5.0) seconds.
Postflow (POST) − The amount of time
that the shielding gas will flow after the arc
has been shut off. Range of this setting is
from (0.0 to 10.0) seconds.
Run−In Speed (R−IN) − The wirefeed
speed prior to the welding arc being struck.
This setting is a percentage of the wirefeed
speed the unit is set to for welding. Range
of this setting is from (X0.10 to X0.99 to
OFF). Example: If the weld wirefeed speed
is 200 and R−IN is X0.50, the run−in
wirefeed speed is 100.
.
Additional PROFILE PULSE menu
items may appear in the SETUP
MENU when PROFILE PULSE is act-
ive. See Section 7-5.
OM-239 210 Page 23