C. Description Of Controls (Use With Sections A And B)
1
Power Switch
Turn this switch ON to energize the VL-M4
Controller. For this unit to operate, 115 vac
must be supplied to this controller on pins G
and I of the 14-pin receptacle or on terminals
31 and 32 of terminal strip TE2. Turn switch
OFF to shut down the controller.
2
Wire Speed Control
This control adjusts the rate or speed at
which welding wire is fed into the weld.
3
Inch Up/ Inch Down Switches
These Inch or Jog switches are momentary
push buttons which energize only the drive
motor allowing for a cold wire jog. The weld-
ing wire jogs at the rate set by the Run-In
Speed Control. To advance the wire out of
the gun, press the Inch Down switch. To re-
OM-189 530 Page 22
tract the wire into the gun, press the Inch Up
switch.
4
Stop Switch
Press the Stop button to end the weld cycle.
Pressing this button initiates the Burnback
delay timer and the Burnback portion of the
weld cycle.
5
Start Switch
After pressing the Start button, flux valve
relay CR5 energizes immediately and sup-
plies 115 VAC to an external flux valve via
terminal 52 on terminal strip TE1 and termi-
nal 32 on TE2. Preflux time can be adjusted
by the knob on CR6. After this timer times
out, the flux valve relay remains energized
and the weld cycle begins. The weld contin-
ues until the stop button is pressed.
6
Output Control
This control adjusts the output of the welding
power source. If using a CV (Constant Volt-
age) machine, this control adjusts voltage. If
using a CC (Constant Current) machine, this
control adjusts current.
7
Weld Meters
The meters are provided to monitor the weld-
ing operation (either AC or DC). They are not
intended for exact voltage or amperage
measurements. The Voltage Sense lead
must be properly connected for the voltme-
ter to receive a signal and function correctly.