Miller Subarc DC 1000 Manual do Proprietário - Página 13

Procurar online ou descarregar pdf Manual do Proprietário para Gerador portátil Miller Subarc DC 1000. Miller Subarc DC 1000 48 páginas.

Miller Subarc DC 1000 Manual do Proprietário
NOTE

2-1. Specifications

Voltage
AC or DC
Range in
Rated Output
CV Mode
1000 A at 44 V,
100% Duty Cycle;
100% Duty Cycle;
25–44 V
1250 A at 44 V,
60% Duty Cycle
*While idling

2-2. Duty Cycle and Overheating

Overheating
SECTION 2 – INSTALLATION
With 60 Hz input power, the ac weld output of this unit is 10 Hz. With 50 Hz input,
the ac weld output is 8.33 Hz.
Amperage
Max. Open-
Range in
Circuit
CC Mode
Voltage
250–1250 A
71 V
100% Duty Cycle At 1000 Amperes
Continuous Welding
0
Minutes
RMS Amps Input at Rated Load Output,
3-Phase at NEMA Load
Voltages and Class I Rating
380/400/415 V
460 V
(50/60 Hz)
(60 Hz)
143
143
124
124
(3*)
(3*)
15
OR
Reduce Duty Cycle
575 V
(60 Hz)
KVA
100
100
98
98
(3*)
(2.37*)
(0.95*)
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, high temperature
shutdown light turns On, thermo-
stat(s) opens, output stops, and
cooling fan runs. Wait fifteen min-
utes for unit to cool. Reduce amper-
age or duty cycle before welding.
Y Exceeding duty cycle can
damage unit and void war-
ranty.
A/V
duty1 4/95 – SA-181 560
OM-2221 Page 9
KW
53
53