2-1. Specifications
Voltage
AC or DC
Range in
Rated Output
CV Mode
1000 A at 44 V,
100% Duty Cycle;
100% Duty Cycle;
25–44 V
1250 A at 44 V,
60% Duty Cycle
*While idling
2-2. Duty Cycle and Overheating
Overheating
SECTION 2 – INSTALLATION
With 60 Hz input power, the ac weld output of this unit is 10 Hz. With 50 Hz input,
the ac weld output is 8.33 Hz.
Amperage
Max. Open-
Range in
Circuit
CC Mode
Voltage
250–1250 A
71 V
100% Duty Cycle At 1000 Amperes
Continuous Welding
0
Minutes
RMS Amps Input at Rated Load Output,
3-Phase at NEMA Load
Voltages and Class I Rating
380/400/415 V
460 V
(50/60 Hz)
(60 Hz)
143
143
124
124
(3*)
(3*)
15
OR
Reduce Duty Cycle
575 V
(60 Hz)
KVA
100
100
98
98
(3*)
(2.37*)
(0.95*)
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, high temperature
shutdown light turns On, thermo-
stat(s) opens, output stops, and
cooling fan runs. Wait fifteen min-
utes for unit to cool. Reduce amper-
age or duty cycle before welding.
Y Exceeding duty cycle can
damage unit and void war-
ranty.
A/V
duty1 4/95 – SA-181 560
OM-2221 Page 9
KW
53
53