Trouble shooting guide
A. Can not self priming
B. Less output
C. Big noise
D. Motor can not start up
E. Motor can not start up but with noise
F. Leaking after a period of working
A
B
C
D
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
By Aquaristikwelt24
E
F
Possible cause
Air in
Transparent plastic cover
leaking
Wrang direction of motor
High absorption
Wrang voltage
No water in filter basket or
pump body
No water in seif priming
pipe
Blockage in filter basket
The diameter of suction
pipe is smaller than
discharge pipe
Blockage in discharge pipe
Trash in pump body
Protection fail
No power or damage to
capacitance
Entangle of impeller
X
Damage to mechanical
X
seal or trash absorb on it
www.aquaristikwelt24.de
Solutions
Check the mechanical seal
Clean the transparent
plastic cover and check the
gasket
Check the electrically
Adjust the absorption
Check your voltage
Full the filter basket or
pump body with water
Fill the seif priming pipe
with water
Clean filter basket
Adjust the diameter of the
pipes
Check filter basket and
discharge pipe
Clean pump body
Change protection
Check fuse and change
capacitance
Clean impeller
Change the mechanical
seal or clean it
10 |
e
S e i t