AQUAPHOR RO-101S Manual do Proprietário - Página 4
Procurar online ou descarregar pdf Manual do Proprietário para Sistemas de filtragem de água AQUAPHOR RO-101S. AQUAPHOR RO-101S 20 páginas. Reverse osmosis system
Também para AQUAPHOR RO-101S: Manual do Proprietário (20 páginas), Manual do Proprietário (16 páginas)
1. Operational parameters, Cont.
Table 1. The dependence of minimum necessary operating pressure of the water purifier from
mineralization.
Mineralization,
mg-equ/l
2
4
6
8
10
ATTENTION
The efficiency of RO-101S depends on the incoming tap water mineralization and tap water
pressure (please see Table 1). The recommended operation of RO-101S requires tap water
pressure of at least 29.01 psi / 2 bar.
When tap water pressure is less than illustrated in the Table 1, it is highly recommended to
install a booster pump in order to obtain drainage ratio.
2. Safety instructions
Warning: RO-101S must be applied to potable water only.
It is highly recommended that a water treatment specialist is hired to install and maintain this appliance.
When installing the appliance into a local water supply, it is recommended that you conduct a full water
analysis. If the water analysis does not correspond with the requirements, the life of the filtration and membrane
cartridges may be significantly reduced. In this case, it is recommended to use auxiliary water treatment sys-
tems (e.g. mechanical filter, de-ironing filter with, or alongside a water softener). It is recommended that you only
use microbiological safe water with your Reverse Osmosis system appliance.
Caution: Do not use water that is microbiologically unsafe or water of unknown quality without
adequate disinfection before or after using the appliance.
Caution: Reverse Osmosis water should not be run through copper tubing as the purity of the
water will leach copper and cause an objectionable taste in the water. Additionally, it will form
pinholes in the tubing. Be sure to follow any state or local regulations.
Caution: The Reverse Osmosis system is designed to be connected to cold water only. Never
run warm or hot water through your appliance.
4
Minimum pressure
psi
29.01
36.26
43.51
58.02
87.02
AQUAPHOR RO-101S REVERSE OSMOSIS SYSTEM
bar
2
2.5
3
4
6