9. Starting RO, Сont.
Step 2. Preparing RO for operation
Rotate the three latches 90 degrees in a counterclockwise direction and remove the water filter cap
‰
(figure 2).
Remove the service cap (figure 1; position
‰
10b), which is located under the water filter cap.
Remove the shrink film from the cartridges.
‰
Rinse the sealing O-Rings of the cartridges
‰
and service cap.
Arrange the cartridges in the exact order, as
‰
demonstrated in Table 2. For convenience,
the stop buttons of the collectors have the
different color.
Set the shutoff valve on the connection node into the open position, as shown on figure 4.
‰
Leave the clean water faucet open for 10 minutes.
‰
The noise during the flushing of the cartridges is not a defect.
Close the clean water faucet.
‰
Step 3. Flushing the membrane cartridge unit
Set the shutoff valve on the connection node into the closed position, as shown on figure 5.
‰
Remove the service plug and install membrane cartridge.
‰
Interchange the K5 and K2 cartridges.
‰
Turn the shutoff valve on the connection node into the open position.
‰
Open the clean water faucet, then wait for the water to start flowing.
‰
Let the water flush through RO for 1 hour.*
‰
Close the clean water faucet.
‰
Step 4. Flushing the conditioning cartridge K7M
Close the clean water faucet and fill in the storage tank. This will take 30–50 minutes, depending on water
‰
pressure.
Open the clean water faucet and then wait until all of the water flows out from the storage tank.
‰
Repeat these steps two more times.
‰
Close the clean water faucet.
‰
When the tank is full, RO is ready for operation.
‰
Note: In total, the general flushing of filter and membrane cartridges and startup time will take
you about 3 hours.
* Depending on the storage, transportation and operation conditions, the complete flushing of membrane cartridge may
take up to 24 hours.
14
Table 2. Positions of RO cartridges
in preparation for operation
Stop button colors
BLACK
BLUE
RED
WHITE
AQUAPHOR RO-101S, RO-102S
Cartridge type
K2
K5
Service Cap
K7М