3.2 Clocking BMB3 To External Word Clock
1.
Set BMB3 front panel to EXT.
2.
Open Dante Controller, select DEVICE INFO.
3.
Double Click on device "BMB3-xxxxxx".
4.
Click on CLOCK STATUS. (Image 18).
5.
Set BMB3 to "Preferred Master", and "Enable to sync to
External".
6.
Make sure each device including host PCIe Card is set to correct
sample rate in Device Config (see 2.16 and 2.17).
Image 18: BMB3 on External Clock. BKII Dante Card is also synced to External clock.