Jet Tool

This wrench is used to tighten the small 2 inch (5cm)diameter jets when needed.
To tighten the jets, insert the hex portion of the wrench into the hexagon hole at the base of the jet and turn
clockwise. Do not over tighten.
SITUATION
NO HEAT OR HEAT TOO LOW
JETS WON'T COME ON
NO CONTROL DISPLAY OR FUNCTIONS
LOW WATER FLOW
NO AIR BUBBLES IN JET
SPA IS LEAKING
NO SPA LIGHT
SLOW WATER DRAIN
NO WATER FLOW FROM JETS
T
r
o
u
b
l
T
r
o
u
b
l
PROBABLE CAUSE
Operating while spa cover is open.
Dirty filter
No power to spa control.
No power to spa control.
Dirty filter.
Low water level.
Air control valve in the closed position.
Spa drain valve and cap partially open.
Burned out bulb.
Drain valve not fully opened.
Dirty filter.
Kinked garden hose
Air lock in pump
e
s
h
o
o
t
i
n
g
G
u
i
d
e
e
s
h
o
o
t
i
n
g
G
u
i
d
e
ACTION
Ensure that spa cover is properly closed.
Remove filter cartridge and clean.
Check the GFCI plug, circuit breaker and/or disconnect switch.
Check the GFCI plug, circuit breaker and/or disconnect switch.
Remove filter cartridge and clean. Pg. 10
Make sure water level in spa is correct.
Open venturi dials. Pg. 10.
Ensure that drain valve and cap are fully closed. Pg. 8
Replace bulb. Pg. 13
Ensure that valve is fully open. Pg. 8
Remove filter cartridge and clean. Pg10
Ensure drain hose is not kinked and is in a downhill direction.
Purge the pump. Pg. 16