To facilitate lamp removal, ensure there is enough space at the lamp connector end
to safely remove the UV lamp and/or quartz sleeve (See Figure 2). The controller
will require a ground fault circuit interrupter (GFCI or GFI) outlet and should be
mounted beside or above the reactor. PLEASE NOTE: All Aquasana UV disinfection
systems are intended for indoor use only as they should not be exposed to the
elements.
Installation
Step 1: The reactor can be installed either
horizontally or vertically using the clamps provided.
Vertical installation is the preferred method with the
inlet at the bottom (lamp connection at the top) as
it allows any air that may be in the lines to be easily
purged from the system.
Step 2: The use of a by-pass assembly is
recommended as it will allow you to isolate the
UV reactor. This will allow for easier access in case
maintenance is required (See Figure 3).
Step 3: Use the supplied fasteners to mount the
UV reactor to wood or drywall. If mounting to an
alternate material you will need to purchase the
proper corresponding fasteners.
Step 4: For water supplies where the maximum
flow rate is unknown, a flow restrictor is
recommended so that the rated flow of your
particular Aquasana system is not exceeded. The
flow restrictor should be installed on the outlet port
of the reactor.
Step 5: It is recommended to have a licensed
plumber connect the UV reactor to the water supply
and may be a requirement depending on where you
are located.
out to hot
& cold water
Figure 3
By-pass assembly
in from
water main
bypass
loop
leave at least
an additonal
reactor length
to facilitate
lamp and sleeve
removal
Figure 2
Lamp Removal Spacing
Note: Installation of your
Aquasana disinfection
systems shall comply with
applicable provincial/
state & local regulations.
7