AQUASCAN INTERNATIONAL KE Series Manual - Página 8

Procurar online ou descarregar pdf Manual para Localizador de peixes AQUASCAN INTERNATIONAL KE Series. AQUASCAN INTERNATIONAL KE Series 20 páginas.

Get more information about the counting process:

It is possible to get more information about the counting. The counter will remember the 15 latest
counting operations. The Registration Unit(s) does not need to be connected in order to access the
information.
The display shows:
WEIGHT(g) Cx:
At this point special commands may be given. When the Delete key is pressed at the start of the
Weight a ? is displayed. The next character will overwrite the ?. If Delete is pressed again, the ? will
disappear.
WEIGHT(g) Cx:

Top level menu

:
1:Clock
3:Results
2:Params

Clock menu

Clock menu, date submenu:
Date:05-15-2006 New?
If Yes is selected the month is first set by two digits and Enter, then day in month, and finally year is
set with four digits. When date is set the operator should select No or Stop to enter the time of day
submenu.
Clock menu, time of day submenu:
Time: 09:44:13 New?
If Yes is selected the hour is first set by two digits and Enter, then minutes, and finally seconds is set
by two digits. When the time is correct the operator should select No or Stop in order to go back to
top level menu.

Parameters menu:

1:New WGF 2:New CTF
C1:
1000
The Weight factor is used to adjust the displayed weight.
The Weight factor will be limited to values from 500 to 2000 (-50 %, +100 %), and may be adjusted
for each channel.
A value of 1000 means no weight adjustment.
If the Weight factor for C1 is set to 500 the displayed weight for C1 will be one half of the value
compared to if the weight factor was 1000. In the same manner, if the weight factor for C2 is set to
2000 the displayed weight for C2 will be twice the value displayed if the weight factor was 1000.
Calculated weight factors should be rounded to closest integer.
where x is 1 or the channel number of the first connected Registration Unit.
Menu is entered in order to start the menu system.
1 selects the Clock menu, 2 selects Parameters menu,
3 selects Results menu, Stop leaves the menu system.
Yes selects date adjustment.
No or Stop continues to time of day submenu.
Yes selects time of day adjustment.
No or Stop goes back to top level menu.
1 selects new weight factor (WGF) for displayed channel
2 selects new count factor (CTF) for displayed channel
1000
> and < displays next and previous channel. Stop goes back
to top level menu.
Page 8 of 20