Panasonic AG-DVC200E Manual de Instruções - Página 39
Procurar online ou descarregar pdf Manual de Instruções para Câmara de vídeo Panasonic AG-DVC200E. Panasonic AG-DVC200E 44 páginas. Digital video camera recorder
Warning system
When an error or a problem is detected immediately after the power is turned on or while an operation is underway, the WARNING lamp and
lamps inside the viewfinder serve to alert the user.
∫ SLACK
WARNING lamp
Flashes four times per second.
Tally lamp
Flashes four times per second.
Viewfinder
The SLACK display flashes.
Description of warning
Trouble has occurred in the motor, solenoid or
other mechanism.
VTR unit operation
The tape stops travelling.
trouble has been detected, the power is turned
off.
Remedial action
Check the error code (see page 40) shown in
the viewfinder and consult your nearest service
centre.
∫ REC WARNING
WARNING lamp
Flashes four times per second (for over 3
seconds during recording).
Tally lamp
Flashes four times per second (for over 3
seconds during recording).
Viewfinder
The REC WARNING display flashes (for over 3
seconds during recording).
Description of warning
A problem has occurred with the recording
control signals.
VTR unit operation
Recording continues but it may not be
performed properly while the warning is
displayed.
Remedial action
This problem has occurred with the control
signals inside the unit. Consult your nearest
service centre.
∫ RF
WARNING lamp
Flashes
recording).
Tally lamp
Flashes
recording).
Viewfinder
The RF display flashes (during recording).
Description of warning
The video heads are clogged. This problem
occurs in the recording system.
VTR unit operation
The cleaning roller is actuated to clean the
heads (max. 3 seconds). Recording continues
but it may not be performed properly.
The warning display remains flashing up to the
REC/PAUSE mode. It goes out when the unit's
mode is transferred from REC/PAUSE.
Remedial action
Clean the heads. If recording still cannot be
performed properly even after they have been
cleaned, turn off the unit's power, and consult
your nearest service centre.
When solenoid
four
times
per
second
(during
four
times
per
second
(during
38 (E)
∫ SERVO
WARNING lamp
Flashes four times per second (during recording
and playback).
Tally lamp
Flashes four times per second (during recording
and playback).
Viewfinder
The SERVO display flashes (during recording
and playback).
Description of warning
The servo is out of sync.
VTR unit operation
Operation continues but it may not be performed
properly.
Remedial action
Turn off the unit's power, and consult your
dealer.
∫ HUMID
≥ Lights when condensation has been detected.
WARNING lamp
≥ Flashes once a second from 10 minutes after
the condensation detection has been released
for a duration of 80 minutes.
≥ Flashes four times per second starting at the
Tally lamp
time when the condensation was detected
until 10 minutes have elapsed after the
condensation detection was released.
≥ The lamp turns off 10 minutes after the
condensation detection status is released.
Viewfinder
The HUMID display flashes starting at the time
when the condensation was detected until 90
minutes have elapsed after the condensation
detection was released.
Description of warning
Condensation has formed.
VTR unit operation
The recording operation continues but it will stop
if the tape sticks. For 80 minutes after the
condensation detection was released, the
operation which causes the drum to rotate is not
acknowledged.
Remedial action
Stop the tape travel, and turn off the unit's
power. If the HUMID display fails to go out even
after the power has been turned back on, wait
until it goes out.
∫ TAPE NEAR END
WARNING lamp
Flashes once per second (during recording).
Tally lamp
Flashes once per second (during recording).
≥ The remaining tape display flashes (in the EE
Viewfinder
mode)
≥ = flashes for 3 seconds one minute before
the tape-end.
Description of warning
The tape is approaching its end (2 minutes
remain).
VTR unit operation
Operation continues.
Remedial action
Replace the cassette tape as necessary.