AQUASYSTEM AMH1-25FC Manual de operação - Página 7
Procurar online ou descarregar pdf Manual de operação para Bomba de água AQUASYSTEM AMH1-25FC. AQUASYSTEM AMH1-25FC 12 páginas. Air-motor type centrifugal pump
How To Use
Before Operation starts
1. Be sure again if the pump, flange and other pipe connectors are not
loosened. Also, be sure if bolts and/or screws at each part of
motors/pumps are firmly fixed.
2. Supplying Air Pressure:0.4~0.6 MPa
3. Acceptable viscosity:Up to 2,000 cP
4. When the pump is disassembled due to inspection and/maintenance,
be sure if all parts are firmly fixed, every time when re-assembled.
5. Once again, we advise our valuable customers carefully to read our
Operation Manual (P. 1-4).
During Normal Operation
1. In case the pipes, hoses and valves etc. are connected,
be sure that they are firmly connected each other.
2. Ground wire
before
3. Air-plug should be gradually opened. Control the discharging volume
with air-valve angle.
※In case of "Under dry condition" or "Under non-use condition for
a long time", be sure, first of all, to fill the liquid (approx. 200 cc)
through the priming plug located at upper portion of pump.
4. Be sure that vibration and/or noise are stable.
Stop Operation
1. Close air-plug. (No discharging operation is allowed.)
2. The liquid can be taken out through the drain plug.
(If the liquid remains in a pump, it may generate the rust inside
of pump, which may cause mechanical troubles and/or damage
the performance.)
operating by all means.
Priming and Drain plug
6
Air Plug
Ea
Kits r