HP 5120 EI Series Ficha de dados - Página 11

Procurar online ou descarregar pdf Ficha de dados para Interruptor HP 5120 EI Series. HP 5120 EI Series 17 páginas.

Data sheet | HP 5120 EI Switch Series
HP 5120 EI Switch Series
Specifications (continued)
Environment
Operating temperature
Operating relative humidity
Nonoperating/Storage
temperature
Nonoperating/Storage relative
humidity
Acoustic
Electrical characteristics
Frequency
Maximum heat dissipation
AC voltage
Maximum power rating
Idle power
PoE power
Safety
Emissions
Management
HP 5120-24G EI Switch (JE066A)
32°F to 113°F (0°C to 45°C)
10% to 90%, noncondensing
-40°F to 158°F (-40°C to 70°C)
5% to 95%, noncondensing
ISO 7779
50/60 Hz
212 BTU/hr (223.66 kJ/hr)
100–240 VAC
62 W
35 W
UL 60950-1; EN 60825-1 Safety of
Laser Products-Part 1; EN 60825-2
Safety of Laser Products-Part 2; IEC
60950-1; CAN/CSA-C22.2 No. 60950-1;
Anatel; ULAR; GOST; EN 60950-1/A11;
FDA 21 CFR Subchapter J; NOM; RoHS
Compliance
FCC part 15 Class A; VCCI Class A; EN
55022 Class A; CISPR 22 Class A;
ICES-003 Class A; ANSI C63.4 2003;
ETSI EN 300 386 v1.3.3; AS/NZS
CISPR 22 Class A; EN 61000-3-2; EN
61000-3-3; EN 61000-4-2; EN 61000-
4-3; EN 61000-4-4; EN 61000-4-5;
EN 61000-4-6; EN 61000-4-11; EN
61000-3-2:2006; EN 61000-3-3:1995
+A1:2001+A2:2005; EMC Directive
2004/108/EC; FCC (CFR 47, Part 15)
Class A
IMC—Intelligent Management Center;
command-line interface; Web browser;
SNMP Manager
HP 5120-48G-PoE+ EI Switch with 2
Interface Slots (JG237A)
32°F to 113°F (0°C to 45°C)
10% to 90%, noncondensing
-40°F to 158°F (-40°C to 70°C)
10% to 90%, noncondensing
ISO 7779
50/60 Hz
614 BTU/hr (647.77 kJ/hr)
100–240 VAC
920 W
78 W
740 W
UL 60950-1; EN 60825-1 Safety of
Laser Products-Part 1; EN 60825-2
Safety of Laser Products-Part 2; IEC
60950-1; CAN/CSA-C22.2 No. 60950-1;
Anatel; ULAR; GOST; EN 60950-1/A11;
FDA 21 CFR Subchapter J; NOM; RoHS
Compliance
FCC part 15 Class A; VCCI Class A; EN
55022 Class A; CISPR 22 Class A;
ICES-003 Class A; ANSI C63.4 2003;
ETSI EN 300 386 v1.3.3; AS/NZS
CISPR 22 Class A; EN 61000-3-2; EN
61000-3-3; EN 61000-4-2; EN 61000-
4-3; EN 61000-4-4; EN 61000-4-5;
EN 61000-4-6; EN 61000-4-11; EN
61000-3-2:2006; EN 61000-3-3:1995
+A1:2001+A2:2005; EMC Directive
2004/108/EC; FCC (CFR 47, Part 15)
Class A
IMC—Intelligent Management Center;
command-line interface; Web browser;
SNMP Manager
HP 5120-24G-PoE+ EI Switch with 2
Interface Slots (JG236A)
32°F to 113°F (0°C to 45°C)
10% to 90%, noncondensing
-40°F to 158°F (-40°C to 70°C)
5% to 95%, noncondensing
ISO 7779
50/60 Hz
425 BTU/hr (448.38 kJ/hr)
100–240 VAC
495 W
55 W
370 W
UL 60950-1; EN 60825-1 Safety of
Laser Products-Part 1; EN 60825-2
Safety of Laser Products-Part 2; IEC
60950-1; CAN/CSA-C22.2 No. 60950-1;
Anatel; ULAR; GOST; EN 60950-1/A11;
FDA 21 CFR Subchapter J; NOM; RoHS
Compliance
FCC part 15 Class A; VCCI Class A; EN
55022 Class A; CISPR 22 Class A;
ICES-003 Class A; ANSI C63.4 2003;
ETSI EN 300 386 v1.3.3; AS/NZS CISPR
22 Class A; EN 61000-3-2; EN 61000-
3-3; EN 61000-4-2; EN 61000-4-3;
EN 61000-4-4; EN 61000-4-5; EN
61000-4-6; EN 61000-4-11; EN
61000-3-2:2006; EN 61000-3-3:1995
+A1:2001+A2:2005; EMC Directive
2004/108/EC; FCC (CFR 47, Part 15)
Class A
IMC—Intelligent Management Center;
command-line interface; Web browser;
SNMP Manager
11