HP StorageWorks FC Entry Switch 8B Manual do utilizador - Página 11
Procurar online ou descarregar pdf Manual do utilizador para Interruptor HP StorageWorks FC Entry Switch 8B. HP StorageWorks FC Entry Switch 8B 38 páginas. Isl trunking user's guide (version 3.0)
Também para HP StorageWorks FC Entry Switch 8B: Manual do utilizador (44 páginas), Manual do utilizador (44 páginas), Manual do utilizador (38 páginas), Manual do utilizador (37 páginas), Manual do utilizador (30 páginas)
1
Introducing Fabric Watch
Figure 1-1 shows a typical example of an error counter with a temperature range threshold.
Figure 1-1
Example of Range Threshold: Temperature (Celsius)
Rising/Falling Threshold
A rising/falling threshold tracks whether an element is on the desired side of a boundary. It includes
an upper and lower boundary, and the buffer zones are always zero. Events can be selected for
transitions between the boundaries. Rising/falling thresholds are typically used for rate based
counters. Rate based counters are all counters with a time base set to something other than "none",
this includes the TX Perf and RX Perf counters.
Fabric Watch User's Guide
1-3