Aquatel D110 Manual de instruções - Página 9

Procurar online ou descarregar pdf Manual de instruções para Monitor Aquatel D110. Aquatel D110 12 páginas. Wireless level monitor
Também para Aquatel D110: Manual de instruções (13 páginas)

Aquatel D110 Manual de instruções
tank unit setup -
T o remove a Tank Unit, select Remove tank and select which tank unit you wish
to remove. Please note that at least one Tank Unit must always be paired with
the Display, you will need to add a new Tank Unit before you can remove the last
one. You can configure any Tank Unit paired with the Display Unit by selecting
"Configure tank unit", here you will be able to change the name, move to another
position, change the alarm levels, top air gap etc.
system
System Settings
measurement interval
Y ou can adjust the update interval from 1-30
minutes on each Tank Unit paired, this is
helpful if you need more frequent updates on
smaller tanks/cisterns or less frequent updates
on a larger tank/cistern you are monitoring.
The longer the update interval the longer the
batteries will last in the Tank Unit.
note:
- When the tank unit is in test mode the level
information updates every 20 seconds
- When out of test mode the tank unit will update at the next scheduled reading interval.
to force an update immediately, remove the tank unit lid and press the reset button.
reading beeps:
reading beeps can be turned off under the System Settings menu.
lock unit (For aquatel authorised installers only):
to prevent tampering and changes to alarm level settings. (Changes can still be made to the
clock and measurement interval)
note: only aquatel authorised installers are able to obtain unlock codes from the login section of
the aquatel website.
Factory reset:
note: the unit can not be reset if the unit is locked.
continued
When set to ON the Display Unit beeps when a new reading is received,
Reset all settings to factory defaults.
System installers can lock the unit
– 8 –