Persons coming in contact with wastewater, must immediately wash all exposed areas with disinfecting cleaner and contact your personal physician. Failure
to do so could result in severe sickness or death.
MAINT.
AREA
OPERATION
BLOWER
INTAKE FILTER
CONTROL
AUDIO & VISUAL FUNCTION
PANEL
BEING AERATED
REACTION
CHAMBER
SOLIDS REMOVAL
VIEW EFFLUENT
WATER
CHECK ODOR
QUALITY
COLLECT SAMPLE
MEMBRANE
CLEAN IN PLACE
CARTRIDGE
INTENSE OXIDATIVE
CHEMICAL
CLEANING & CITRIC ACID
CLEANING
CHEMICAL CLEANING PROCEDURES
The membrane plates are fragile. Care must be used in cleaning them. Carefully follow the
instructions below. Always keep the membrane plates thoroughly wetted.
Only authorized service personnel are to perform chemical cleaning on the BioBarrier.
Hazardous chemicals and infectious waste material are present when cleaning the system.
Proper protective clothing, equipment and practices must be implemented when attempting the
procedures described below.
CIP (CLEAN IN PLACE) PROCEDURE
The following procedure is to be performed for each membrane
module/stack in the entire system.
1.
Shut OFF air to unit(s) to be cleaned.
2.
Open ball valve on vent/CIP pipe to membrane's discharge pump.
3.
Mix chlorine cleaning solution
a. Each single stack module - Premix 0.8 L (~1/4 gal) household bleach (5.2 – 6.2% NaOHCl (sodium
hypochlorite)) into 10 gallons of tap water. Warm water is best (~80°F/26°C).
4.
Use a funnel to pour this mixture into the CIP pipe.
5.
Close CIP pipe ball valve.
Let the unit sit NOT RUNNING for at least 4 hours (longer is better).
6.
After 4 hours, turn ON the power to the unit (should return to AUTOMATIC operation).
7.
INTENSE OXIDATIVE CLEANING PROCEDURE:
Chlorine and chlorine gas can be lethally toxic. Proper safety precautions as detailed in the Material Safety Data Sheets for the chemical being used must be
followed. Use ONLY the substances mentioned in these instructions. Using additional substances could be lethally hazardous.
1.
Remove membrane unit from the aeration tank. Remove the membrane module from its housing.
2.
Carefully remove any large solids or sludge cake from the surface of the membrane by rinsing each membrane plate with a garden hose.
NOT
touch the surface of the membrane sheet with any foreign substance including a hand.
3.
Prepare a chlorine cleaning solution in a container large enough to fully submerge the membrane module. For every 10 gallons of water mix 0.8
L (~1/4 gal) household bleach (5.2 – 6.2% NaOHCl (sodium hypochlorite)). Typically, 30 gallons of water is needed per module for complete
submergence of the module.
4.
Soak the membrane modules in this solution for a minimum of four (4) hours. The entire module must be submerged for the entire cleaning
period.
5.
Perform citric acid cleaning procedure, if necessary. Place the cleaned membrane back into the aeration tank.
6.
The membrane plates
MUST ALWAYS

REGULAR MAINTENANCE SCHEDULE

MAINT.
NEED
Open blower housing, check to confirm that blower is running (be sure blower is not OFF due to SFR
timer in LTRP state).
Remove wing nut from intake assembly on blower, remove all debris from filter element. Put assembly
back together.
Check the "Setting/Information" screen on the panel for Alarm message and make sure screen is NOT
showing an alarm message.
Remove cover from manhole over BioBarrier® system and check to be sure vigorous boiling is
occurring (unless system is in LTRP with SFR
Check "Bio-Solids Removal" procedure under "DO'S & DON'T'S -in the yard" section of this manual.
Visually observe final effluent of system of BioBarrier system. Effluent should be very clear.
Smell odor at BioBarrier vent, it should be a damp, earthy odor.
Refer to the "COLLECTION OF EFFLUENT SAMPLE" section of this manual.
Check filtration time on control panel. If it exceeded 16:00 hrs in one day and the system floats are
operating correctly, then perform the CIP procedure according to the instructions below.
Perform this cleaning procedure after four consecutive CIP procedures have been performed. See
instructions below for proper procedures.
CLEANING
remain thoroughly wetted, whether during cleaning, storage and transportation.
PROCEDURE
activated).
®
®
DO