Maintenance Guidelines
Keep your compressor and intake filter clean. Any excess dust and debris
on motor or air intake may significantly shorten the life of the compressor.
Diffusers may need regular cleaning in certain water conditions. This may be
every two to five years.
Compressors may need to be rebuilt if running but no longer "pumping air."
Contact your EasyPro dealer for compressor rebuild kits.
If lines become frozen, a small amount of denatured alcohol can be run
down the frozen line to thaw it out. The small amount of alcohol will not
harm fish or biological processes in your pond.
After one or two years of operation, you will possibly notice a sudden drop in air
bubbles. This is a sign the compressor needs new diaphrams or vanes. Rebuild
kits are available to restore like-new performance. Be sure to keep the air filter
clean. Replacement filters are available.
Kit
Part #
PA10
PA12
PA50
PA75
PA100

Troubleshooting

Low
High
Pressure
Pressure
Compressor will not start
Compressor will not start
Low
High
Air Flow
Air Flow
Compressor
DC22
DC12
RV33
RV75
RV100
Compressor Troubleshooting
Compressor
Excess
Overheating
Noise
Diffuser Troubleshooting
Uneven
Burping
Air Flow
Bubbles Cause and Solution
Replacement
Filter/Element
DC22F
ERPF1/ERPF12E
AC432/AC393
AC432/AC393
AC432/AC393
Cause and Solution
Dirty air filter, clean or replace
Valves closed too much, open valves
Worn diaphrams or vanes, rebuild compressor
Plugged/frozen tubing, inspect and repair
Leaky tubing or check valve, inspect and repair
Wrong voltage, check power source
Miswired electrical components, check wiring
Leak in system, check connections and repair
Manifold not set correctly, adjust placement
Damaged or torn membrane, replace
Compressor issue, see above
6
Compressor
Repair Kits
RK22
DC12RK
RV33V
RV75V
RV100V