Bionaire PERMAtech BAP1525RC Folheto de instruções - Página 2
Procurar online ou descarregar pdf Folheto de instruções para Filtro de ar Bionaire PERMAtech BAP1525RC. Bionaire PERMAtech BAP1525RC 2 páginas. Bionaire ionizing air cleaner instruction manual

BAP1525RCW_07EM1.qxd
5/29/07
9:50
Page 2
Jarden Consumer Solutions or an authorized Jarden
AIR CLEANER SAFETY
Consumer Solutions Service Center.
•
WARNING: To reduce the risk of fire or electric shock,
IMPORTANT SAFEGUARDS
DO NOT use this air cleaner with any solid-state speed
control device.
When using electrical appliances, basic safety precautions
•
Always turn the appliance off before unplugging it.
should always be followed to reduce the risk of fire, electric
•
NEVER use detergents, gasoline, glass cleaner, furniture
shock, and injury to persons. These precautions include:
polish, paint thinner or other household solvents to
•
Read all instructions before using the appliance.
clean any part of the air cleaner.
•
To avoid fire or shock hazard, plug the appliance directly
•
The ionizer may cause a static charge to build up on
into a 120V AC electrical outlet.
the air output grill. A static charge may be felt if the unit
•
If the filter is covered by a bag when shipped: Remove
is not properly grounded. To avoid a static charge, plug
plastic bag before use.
the unit's three-prong plug into a grounded outlet, or
properly install a ground adaptor (see PLUG SAFETY).
•
Keep the cord out of heavy traffic areas. To avoid fire
The static charge will not occur if the ionizer is off.
hazard, NEVER put the cord under rugs, near heat
registers, radiators, stoves, or heaters.
•
The ionizer in this appliance produces less ozone than
the UL established limits of 50ppb. However, in high
•
To protect against electrical hazards, DO NOT immerse
concentrations, ozone can be harmful to birds and
in water or other liquids. Do not use near water.
small pets. To prevent ozone buildup, we suggest using
•
Close supervision is necessary when any appliance is
the ionizer in well ventilated areas with the fan on.
used by or near children, or disabled persons.
•
This appliance should only be used in a room with
•
Always unplug the air cleaner before moving or
temperatures between 40° F and 110° F.
cleaning the unit, opening the grill, changing the filters
and whenever the unit is not in use. To disconnect the
PLEASE SAVE THESE
unit, be sure to pull the plug and not the cord.
INSTRUCTIONS
•
NEVER drop or insert any objects into the openings of
the unit.
PLUG SAFETY
•
Do not operate any appliance with a damaged cord or
plug. If the motor fan fails to operate or the unit has
been dropped or damaged in any manner, return
appliance to manufacturer for examination and/or repair.
•
Use appliance only for intended household use as
described in this manual. Any other use not
The cord has a plug (A) as shown. An adapter (C) can be
recommended by the manufacturer may cause fire,
purchased for connecting three-blade grounding-type plugs to
electric shock, or injury to persons. The use of
two-slot receptacles (B).
attachments not recommended or sold by Jarden
The green grounding wire or lug extending from the adapter
Consumer Solutions may cause hazards.
must be connected to a permanent ground such as a properly
•
DO NOT use outdoors.
grounded outlet box. The adapter should not be used if a
three-slot grounded receptacle is available.
•
NEVER place on a soft surface such as a bed or sofa
as this could cause the unit to tip over and block the
This plug will only fit into a grounding type power outlet. If the
air inlet or outlet grills.
plug does not fit into the outlet, contact qualified personnel to
install the proper outlet.
•
Keep unit away from heated surfaces and open flames.
This product is for use on 120 volts. DO NOT ALTER THE
•
DO NOT place anything on top of unit.
PLUG IN ANY WAY.
•
DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
CORD SAFETY
your warranty. The inside of the unit contains no user
•
The length of cord used on this appliance was
serviceable parts. All servicing should be performed by
selected to reduce tangling and tripping hazards.
•
If a longer cord is necessary, an approved extension
cord may be used. The electrical rating of the extension
cord must be equal to or greater than the rating of the
air cleaner (see rating label marked on product).
•
Care must be taken to arrange the extension cord so that
it will not drape over the countertop or tabletop where it
can be pulled on by children or accidentally tripped over.
FEATURES
GET TO KNOW YOUR AIR CLEANER
Your Bionaire
®
air cleaner features a Permanent HEPA-Type
filter that removes up to 99% of airborne dust and pollen as
small as 2 microns and helps reduce smoke, mold spores
and pet dander from the air passing through the filter.
•
Permanent filters can be vacuumed every few months
for easy cleaning.
•
Washable pre-filter captures larger particles and
extends the permanent filter's cleaning cycle.
•
Optional ionizer naturally improves performance and
helps freshen the air.
•
Slim tower design allows placement in almost any
area of the room.
•
Remote control allows convenient operation from
anywhere in the room.
IONIZER
To reduce the risk of electric shock,
This appliance has an optional ionizer feature which, when
THIS PRODUCT IS EQUIPPED
turned on, releases negative ions into outgoing filtered air
WITH A 3-PRONG PLUG, a
to help the air purification process.
grounding type plug that has a third
What Are Ions?
(grounding) pin.
Ions are tiny particles that carry a positive or negative
charge. They exist naturally around us: in the air, water,
and ground. Both positive and negative ions are colorless,
odorless, and completely harmless.
How Does The Ionizer Work?
Negative ions help air purification by attaching themselves
to very small airborne particles in the room. These particles
take on a negative charge and may join with positively
charged particles such as dust, pollen, smoke, and pet
dander to form larger particles. These larger particles are
then more easily captured by the filter system.
IMPORTANT NOTES:
Your ionizer may produce an occasional popping or
cracking sound. This is normal and occurs when a small
buildup of ions is discharged.
After extended use, you may notice dust around the grills
HIGH, MEDIUM AND LOW SPEED SETTINGS
or front panel. This is caused by negative ions exiting the
For optimum air filtration, operate your Bionaire
air outlet, evidence of the ionizer's air cleaning
continuously on the HI setting. Its rugged motor has been
effectiveness. You can remove the dust with a soft brush
designed to give many years of use. For quieter operation
or clean, damp cloth.
(such as in a bedroom), select LOW setting.
Larger particles may be attracted to positively charged
surfaces throughout the home, like walls or floors.
BEFORE USE
•
This may occur more frequently when the filter is
1. Carefully unpack your air cleaner.
nearing the end of its useful product life and unable to
2. Select a firm, level surface with no obstructions to the
capture as many charged particles.
air inlets or outlets.
•
Excessive amounts of pet dander, dust, or smoke may
3. If the filter is covered by a bag when shipped, remove
decrease the life expectancy of the filter(s) and interfere
plastic bag before use and place filters into unit.
with the ionization process.
To help prevent particles from attracting to surfaces
BEFORE USING THE REMOTE CONTROL:
throughout your home:
Your remote control requires (2) AAA batteries for operation.
•
You may want to run the ionizer less often.
Insert batteries and replace cover.
•
Check the condition of filters more frequently.
•
Do NOT mix old and new, alkaline, standard
CAUTION: The ionizer in this appliance produces less
(carbon-zinc) or rechargeable (nickel-cadmium)
ozone than the UL* established limits of 50ppb. However,
batteries.
in high concentrations, ozone can be harmful to birds and
•
For functions available on your remote control, see
small pets. To prevent ozone buildup, we suggest using
OPERATING INSTRUCTIONS.
the ionizer in well ventilated areas with the fan on.
IMPORTANT: Always clean the PERMAtech™ filter at the
OPERATING INSTRUCTIONS
recommended intervals (See CLEANING THE
PERMAtech™ FILTER). Using the ionizer with dirty filters
IMPORTANT:
may result in dirty particles exiting the air purifier and
attracting to walls, carpets, furniture, or other household
•
Remove all plastic bags from filters before use.
objects. These dirty particles may prove difficult to remove.
•
DO NOT POINT FILTERED AIR OUTLET TOWARDS
WALL.
HEPA-TYPE PERMAtech™ FILTER
The PERMAtech™ filter allows easy maintenance and
TO OPERATE YOUR AIR CLEANER:
eliminates the hassle of filter replacement. HEPA (High
1. Press the POWER button (
Efficiency Particulate Air) filters are designed to remove up
to 99% of airborne pollutants, at 2 microns or larger, from
• The air cleaner will turn on at HIGH filtering speed.
the air that passes through them. These include tobacco
2. Select filtering speed by pressing POWER button until
smoke, household dust, pet dander and pollen.
you reach the desired speed - HIGH (
(
) or LOW (
FILTER INDICATOR
The filter indicator light eliminates guesswork by letting you
• The air cleaner will turn off when you press the
know when it is time to clean the filters.
POWER button for 3 seconds at any speed.
3. Press IONIZER button (
REMOTE CONTROL
• IONIZER button works in any mode except when air
The convenient remote control lets you select the filtering
cleaner is turned off.
speed from anywhere in the room.
TO OPERATE THE AIR CLEANER WITH YOUR
REMOTE CONTROL:
1. Press the power button (
*tested and listed by the Underwriters Laboratories, Inc.
• The air cleaner will turn on at HIGH filtering speed.
2. Select filtering speed: HIGH (
®
air cleaner
LOW (
).
3. Turn ionizer ON or OFF.
G
H
F
E
).
), MEDIUM
).
) to turn ionizer ON or OFF.
A. Inlet Grill
F. Filter Indicator Light
B. Washable Foam Pre-filter
G. Ionizer Control
C. Speed Control
H. Ionizer Light
D. Power Indicator
I. PERMAtech
).
E. Filtered Air Outlet
J. Control Panel
), MEDIUM (
) or
Figure 1
C
D
J
A
B
I
TM
Filters