Alpha IP FAL 41011-06 Manual - Página 10
Procurar online ou descarregar pdf Manual para Acessórios Alpha IP FAL 41011-06. Alpha IP FAL 41011-06 17 páginas.
Commissioning
24 V
The pump control is activated or deactivated directly at the base station, or with an Alpha IP room
control unit Display.
6.4.1
Activation/deactivation of the pump control (base station)
The connection terminal (G) can be used for the control of a recirculation pump. For this, set the heat-
ing zone to pump control directly at the device as follows:
1. Press and hold the Select key (B) of the Alpha IP base station approximately for 4 seconds, until the
LED of heating zone 1 flashes in green:
Duration in seconds
0,1
0,2
0
HZ1
Duration in seconds
0,5
1,0
0
HZ1
2. Toggling the pump from active to inactive or vice versa: Press the Select key (B) for 4 seconds.
3. Leaving the menu without changes: Press the Select key shortly.
6.4.2
Activation/deactivation of the pump control (Room control unit Display)
With the Alpha IP room control unit Display, different parameters can be assigned to the pump control.
For this, the parameter P025 in menu UnP1 (see section 8: Configuration) must be changed according
to the requirements.
For parametrisation, one Alpha IP room control unit must have been taught in to heating zone
1. This device can be used for further heating zones.
7 Commissioning
For the commissioning of the Alpha IP base station, at least one Alpha IP room control unit Display,
Display S or Analog must be taught-in to the base station. As an alternative, the base station can be
integrated to the Alpha IP Access Point via the app into the Alpha IP system. If used without Access
10
L1
L2
1
2
1
2
1
2
1
24V
AC
L
N
Display
0,3
0,4
1,5
2,0
230 V
HZ1- HZ10: 24V 1A/HZ
2
1
2
1
2
1
2
1
2
1
2
1
Relay HZ1 230 V ~ 3 (1) A
2
1
2
1
2
1
N
2
L
1
2
1
1
2
2
1
2
Meaning
Pump inactive
(UnP1: P025, value 4)
Pump active
(UnP1: P025, value 0)
Relay
1
2
1
2
1
2
1
2
1
2