V. Configuration of the DIP Switches
The Dip Switches permit to select the following functions:
Dip switch 1:
Dip switches 2 - 6: Configuration of the potentialfree relay
Dip Switch 1
ON Deadman operation
OFF Impulse operation
5
6
Dip Switch 2 in Position ON
Binders 14/15 : contact closes, when the door is completely open
5
6
Dip Switch 3 in Position ON
Binders 14/15: contact closes, when the door is completely closed
5
6
Dip Switch 4 in Position ON
Binders 14/15: contact closes, whenever the door is moving
5
6
Dip Switch 5 in Position ON
Binders 14/15: contact closes during alarm at the binders 37/38
and 39/40 (when contact at binders 37/38 and 39/40 opens)
5
6
Dip Switch 6 in Position ON
Binders 14/15: contact closes, when the door is completely open
Binders 15/16: contact closes, when the door is completely closed
5
6
Deadman or impulse operation
contact at the binders 14/15/16.
Only one of the Dip switches 2 - 6 may
be in position ON.
(When starting the adjustment of the positions when
using a drive unit with integrated position control system,
the control system automatically changes to deadman
operation. Only when all positions have been entered the
control system returns to impulse operation.)