11.2 AMT Specification

Display
Output Signal
Operating Voltage
Maximum Series Resistance:
Sensing element
AutoCal
Factory calibration
Accuracy
Temperature compensation:
Resolution
Repeatability
Operating temperature :
Storage Temperature
Operating Pressure
Operating Humidity (External): Maximum - 95% RH Non-condensing
Sample Flow Rate
Cable Terminations
Cable
Electromagnetic Compatibility (EMC):
Warm Up Time
Fault Conditions
Isolation
Transmitter Enclosure :
Sensor Protection
Probe Material (Wetted Parts): 316 Stainless Steel
Weatherproof Classification:
Mechnical Connection :
Mechanical Warranty
Calibration Warranty
Weight
:
Compatible with the 4-20mA DS1200 Dewpoint Meter.
:
4 to 20mA Linear
:
7V - 28V DC. Reverse polarity protected.
= {40 x (Supply Voltage – 7)}Ω
:
Ultra High Capacitance - Aluminium Oxide Type
:
Field calibration / Span check facility.
:
Supplied with Certificate of Calibration traceable to NPL / NIST
:
± 2°C dewpoint (NPL / NIST traceable for range -90°C to 20°C)
Temperature compensated for operating range.
:
5 µA
:
Better than ±0.3ºC dewpoint
-20°C to +60°C
:
-20°C to +70°C
:
From 1kPa (0.01 barA) to Maximum 35,000kPa ( 350 barA)
:
Independent but ideally 2 to 5 litres per minute. Max: 25 litres/min.
:
IP66 (NEMA4X) rated, size C, DIN EN 175301 connector at the
transmitter and other end terminated with bootlace ferrules.
:
Supplied with 2m standard cable. Nominal diameter 3.4mm, 92ohms/km.
Immunity: Complies with EN 61000-6-1:2001
Emissions: Complies with EN 61000-6-3:2000
:
10 seconds
:
Sensor Open Circuit
Sensor Short Circuit
System Error
:
Sensing Element connected to the 4-20mA loop but isolated from body.
316 Stainless steel body with size C, DIN EN 175301 connector.
:
316 Sintered stainless steel filter - 50 micron
IP66 / NEMA4X when Connector mated to Transmitter.
3/4" UNF (16tpi) with integral Viton "O" ring seal.
:
24 months in case of faulty workmanship and defective parts.
:
12 months subject to usage.
:
175grams (includes connector)
: Output drives to 20.50mA
: Output drives to 20.75mA
: Output drives to 21.00mA