Input Low Voltage Protection
The output is switched off when the input voltage is lower than low
voltage protect value, and auto-switched on when the input voltage
reach low voltage recover value. User can also manually restart the
inverter to switch on output by the „ON/OFF switch‟, when the input
voltage is higher than low voltage protect value.
Low Voltage Protect Value
Low Voltage Recover Value
Input Over Voltage Protection
The output is switched off when the input voltage is higher than ov-
er voltage shut off value, also the output is auto-switched on when
the input voltage drops below over voltage recover value.
Over Voltage Shut Off Value
Over Voltage Recover Value
Fault Protection
The inverter will shut down when the output voltage is error or when
the inverter has inner fault.
Over Temperature Protection
The inverter will shut off when the internal temperature is over-
24V
21.6
25
24V
32
29
9
48V
43.2
50
48V
64
58