DieHard 200.71240 Manual do operador - Página 7

Procurar online ou descarregar pdf Manual do operador para Carregador de bateria DieHard 200.71240. DieHard 200.71240 19 páginas. Battery charger 50/15/2 amp, 6/12 volt, manual 250 amp engine starter
Também para DieHard 200.71240: Manual do operador (18 páginas)

DieHard 200.71240 Manual do operador
7.
fOLLOw ThESE STEPS whEN BATTERY IS OUTSIdE vEhICLE.
A SPARk NEAR ThE BATTERY MAY CAUSE BATTERY EXPLOSION.
TO REdUCE RISk Of A SPARk NEAR BATTERY:
7.1
Check the polarity of the battery posts. The POSITIVE (POS, P, +) battery
post usually has a larger diameter than the NEGATIVE (NEG, N, -) post.
7.2
Attach at least a 24-inch-long 6-gauge (AWG) insulated battery cable to
the NEGATIVE (NEG, N, -) battery post.
7.3
Connect the POSITIVE (RED) charger clip to the POSITIVE (POS, P, +)
post of the battery.
7.4
Position yourself and the free end of the cable you previously attached to
the NEGATIVE (NEG, N, -) battery post as far away from the battery as
possible – then connect the NEGATIVE (BLACK) charger clip to the free
end of the cable.
7.5
Do not face the battery when making the final connection.
7.6
When disconnecting the charger, always do so in reverse sequence of
the connecting procedure and break the first connection while as far away
from the battery as practical.
7.7
A marine (boat) battery must be removed and charged on shore. To
charge it onboard requires equipment specially designed for marine use.
5