15. TROUBLESHOOTING

PROBLEM
The charger will not turn on.
No reading on the Ammeter.
(Needle stays on the left.)
Ammeter reading
stays high.
Ammeter reads less than
selected charge rate when
charging a discharged
battery.
Battery clips do not spark
when touched together.
Charger makes a noticeable
buzz.
POSSIBLE CAUSE
Charger is not plugged in.
No power at the receptacle.
Poor electrical connection.
Clips are not making a good
connection to the battery.
Connections are reversed.
Short or bad cell on the
battery.
2 amp charge rate is being
used.
Battery is severely
discharged.
Wrong battery voltage.
Extension cord is too long or
wire gauge is too small.
Weak cell or sulfated plate in
battery.
Battery is only partially
discharged.
The charger is equipped
with an auto-start feature.
It will not supply current
to the battery clips until a
battery is properly connected.
The clips will not spark if
touched together.
Transformer laminations
vibrate.
11
REASON/SOLUTION
Plug the charger into an AC
outlet.
Check for open fuse or circuit
breaker supplying AC outlet.
Unplug the charger from the
AC outlet, wait 10 seconds,
then plug it back in.
Check for poor connection to
battery and frame.
Unplug the charger and
reverse the clips.
Have the battery checked.
Ammeter may show no
activity at the 2A charge rate.
Continue charging battery for
two more hours. If problem
continues, have the battery
checked.
Verify that the output voltage
of the charger matches the
battery voltage.
Use a shorter or heavier
gauge extension cord.
Have the battery checked.
Continue to charge the
battery.
No problem; this is a normal
condition.
No problem; this is a normal
condition.