AXITEC AC-310MH/120V Manual de instalação - Página 11
Procurar online ou descarregar pdf Manual de instalação para Inversor AXITEC AC-310MH/120V. AXITEC AC-310MH/120V 17 páginas.
4.8.
Grounding
4.8.1. Common grounding hardware (nuts, bolts, star washers, spilt-ring lock washers,
flat washers and the like) is used to attach a listed grounding/bonding device, the
attachment must be made in conformance with the grounding device
manufacturer's instructions. Details for wiring in accordance with the NEC, and
that the grounding method of the frame of arrays shall comply with the NEC,
article 250
4.8.2. Common hardware items such as nuts, bolts, star washers, lock washers and the
like have not been evaluated for electrical conductivity or for use as grounding
devices and should be used only for maintaining mechanical connections and
holding electrical grounding devices in the proper position for electrical
conductivity. Such devices, where supplied with the module and evaluated
through the requirements in UL 1703, may be used for grounding connections in
accordance with the instructions provided with the module. All the PV modules
frame and installing support must be earthed correctly in accord to local
electrical laws, use correct ways of grounding, using suitable grounding wires to
connect PV modules and frame supports. Grounding wires' materials can be
copper, cooper alloy or other conductors which correspond with electrical laws.
Grounding wires must be connected with earth with suitable grounding
electrode. Use Bolt M4, cup washer, grounding wires, flat washer, tooth washer,
screw nut M4 and install like the photo below, torque should be 2N·M-3N·M, this
way it can be grounded firmly.
Materials and sizes are as follow:
Bolt M4: Stainless steel, abbreviated to SS
cup washer: SS Φ9 Φ4.3 h8
grounding wires: single conductor, the cross section
of conductor is no less than 4mm
flat washer: SS Φ9 Φ4.3 h8
tooth washer: SS Φ7.8 Φ4.3 Thickness: 0.5 number of
gears: 11
screw nut M4: SS
Installation Manual
2
Page 10 / 16