AXIXTECH SAF205H Manual de instalação e operação - Página 10

Procurar online ou descarregar pdf Manual de instalação e operação para Amplificador AXIXTECH SAF205H. AXIXTECH SAF205H 16 páginas. Electronic handheld siren

AXIXTECH SAF205H Manual de instalação e operação
Each LV button (LV1, LV2, LV3) may be programmed to automatically turn on any of the auxiliary
button controls (SW1~SW3) except Timed Momentary. These auxiliary button controls may still
be operated manually even if they were turned on automatically. Each time the LV button
changes position, the combined auxiliary button controls are turned on or off. When the LV button
is turned off, the entire auxiliary button controls tied to a position on the LV button is turned off
while the other auxiliary buttons are unaffected.
Set LV buttons (LV1, LV2, LV3) and Auxiliary buttons Combination
1. Activate desired LV button to program.
2. Press the desired auxiliary button to change LED color to Red. Press the auxiliary button
again to change LED color to Green to remove from combination.
3. Once the LV buttons are programmed as desired, save and exit programming mode by
turning DIP-SW2-8 (PRG) switch off.
NOTE: If the unit is turned off before the DIP-SW2-8 (PRG) switch is turned off, the new
programming will not be saved.

OPTION SWITCHES

Various options can be selected by
turning on or off DIP switches located
on the side of the siren. The DIP
SWITCH functions are described below.
(see Appendix 1 for quick reference)
DIP-SW1-1 (HRT_N) HRT Input Polarity – The HRT input is normally activated by a positive
voltage. Set switch on to activate with negative.
DIP-SW1-2 (PKL_N) PKL Input Polarity – The PKL input is normally activated by a positive
voltage. Set switch on to activate with negative.
DIP-SW1-3 (HILO) – HiLo tone replaces Phaser tone by setting this switch on.
DIP-SW1-4 (PHASER_D) – Phaser/HiLo tones are disabled by setting this switch on.
DIP-SW1-5 (HORN_D) – Horn tone is disabled by setting this switch on.hart.
DIP-SW1-6 (SIREN_SW1) – See "Siren Mode settings" chart.
DIP-SW1-7 (SIREN_SW2) – See "Siren Mode settings" chart
DIP-SW1
ON
DIP
1
2
3
4
5
6
7
8
- 9 -
DIP-SW2
ON
DIP
1
2
3
4
5
6
7
8
SAF205H Siren_v.1