Alphalux SureScan ALXPIR Instruções - Página 4
Procurar online ou descarregar pdf Instruções para Acessórios Alphalux SureScan ALXPIR. Alphalux SureScan ALXPIR 4 páginas. 10a, 240v, 10 metre range
TYPICAL WIRING DIAGRAM
ADJUSTING THE CONTROLS:
It is assumed for the purpose of these instructions that the sensor will be connected to a floodlights
(total load <10 amps).
Time Adjustment
Lux Adjustment
Sensitivity Adjustment
ADJUSTMENT CONTROLS DIAGRAM
75mm
The controls for 'TIME' , 'LUX' and 'SENS' (sensing distance) are all adjusted from the base of the sensor
head and are adjusted by the use of a small flat screwdriver. Care should be taken not to apply excessive
force to these controls.
TIME CONTROL
The 'TIME' control adjusts the length of time that the sensor remains on after being triggered. The time can
be adjusted from a minimum of 5 seconds (-) to a maximum of 7 minutes (+). This control can be adjusted at
any time with immediate effect however adjustments during the 'on' cycle should be avoided.
LUX CONTROL
The 'LUX' control allows the user to determine at what level of background light the unit will function. If the
control is moved to the sun position
the unit will trigger under full daylight conditions and if the control is
moved to the moon position
the units will only trigger in complete darkness.
As a guide the setting for triggering at dusk is when the control is ¾ the way between the
symbols.
Tip: To ensure triggering at your preferred light level, your initial set-up adjustment should be carried out at
the time of day you require your lights to illuminate. When the ambient light has reached your preferred level,
simply adjust your sensor to the point where your flood light illuminates.
SENSING DISTANCE CONTROL
The 'SENS' control allows the user to control the distance at which the unit will detect movement. Moving
the control (+) position sets the sensing range to maximum (approx.10 metres), while moving the control to
the (-) position sets the sensing range to a minimum (approx.1 metre).
SET UP AND ADJUSTMENT
Initial set up can be made during normal daylight hours with the final 'LUX' adjustment made later during the
required ambient light level:
1. Turn the power to the unit off at the wall light switch.
2. Adjust the 'TIME' control to minimum (-) on time.
3. Turn the 'LUX' control to
for daylight operation setting.
4. Turn the power on. (Note: Floodlights will remain on for approx. one minute as the unit resets and warms
up.)
5. Direct the sensor head window towards the area that requires monitoring.
6. Create movement in the monitored area and adjust the 'SENS' control until the correct triggering distance
has been achieved.
7. Increase the 'TIME' adjustment to your required floodlight illumination time.
8. The 'LUX' adjustment can also be made at this time, however its strongly recommended that the final
adjustment to the 'LUX' control is best made at the time of day when the background lighting level is
correct.
AUTOMATIC OR MANUAL MODE OPERATION
Your sensor unit can be operated in either an automatic or manual over-ride mode.
- The automatic mode will function as described above with the floodlights triggered by motion and
remaining illuminated for the selected time.
- The manual over-ride will allow the floodlights to remain on continuously.
The user can switch between manual and automatic modes with the light power switch.
and