Warning
The following warnings must be exactingly observed:
Failure to comply with the warnings may result in fire, property
damage, electric shock, injury or death.
To prevent suffocation, electric shock, injury or death, the customer
is responsible to ensure that children shall NOT access the product.
The product shall not be modified, disassembled or serviced.
The product shall be shut down if the outdoor air temperature
exceeds 35ºC or 95ºF.
The vents (A and C) of the product shall NOT be blocked at all.
The enclosure shall not be opened when the product is powered.
NOTE
The manufacturer
supplies third-party
The electrical parts of the product shall not be touched even if the product
locks that the customer
has been shut down. The electrical parts are the fans (F and G),
may install to shut the
power bar (I), and supply fan controller (J).
door of the enclosure.
As soon as possible, the power supply cord (E) shall be safely
disconnected from the electrical mains if there is a spillage of liquid on or
around the product.
The power bar (I) shall only be connected to an electrical receptacle that is
permanently installed in a building.
The power bar (I) shall not be connected to a relocatable power tap.
There shall be no connection of any external devices to the power bar (I).
The cables of the fans (F and G) shall not be disconnected from the
power bar (I).
NOTE
The supply fan controller (J) shall not be adjusted in order not to disrupt
the calibration of the product.
A strip of paper tape is
attached to the supply
fan controller (J) on a
parallel axis to the
calibrated position of
the controller knob.
3
Installation
The following points shall be strictly observed when installing the product:
The product shall not be installed near hazardous or toxic materials.
NOTE
The product shall not be
installed at a location
The product shall only be installed in either vertical or horizontal
where there is probable
orientations and shall not be positioned at an oblique angle.
contact with liquids.
For vertical orientation, the supply vent (A) shall face upwards as
indicated in Figure 1(a). There is no restriction on the horizontal
orientation of the product provided the exhaust vent (C), exhaust
duct (D), and power supply cord (E) are not obstructed.
NOTE
The product can be placed on the floor or a sturdy table.
Professional help may be needed to install the product on a wall.
The product shall be
carefully positioned
such that it may not trip
The vents (A and C) and ducts (B and D) shall NOT be connected
and cause property
to external appliances such as dryers, fans, furnaces, etc.
damage or bodily injury.
The product shall be installed in the conditioned space of a building where
NOTE
the temperature and relative humidity of air are within the range of
The product shall not be
installed at a location
22ºC – 24ºC and 35% – 50%, respectively.
where there is excessive
heat or exposure to
The product shall not be powered until the ducts (B and D) are installed.
direct sunlight.
NOTE
A ventilation kit (not bundled with the product) is needed to install the two
ducts (B and D) such that air can securely and simultaneously be supplied
The ports of the
ventilation kit shall be
to and expelled from the building space.
4" (~10.2 cm).
The ventilation kit can interface with the outdoors though a window, door
NOTE
or wall as illustrated in Figure 3. If the product is vented through a wall,
The product is
calibrated to an air flow
the customer is responsible for complying with all applicable codes.
rate of ~10 CFM.
To power the product, connect the plug of the power supply cord (E) to
NOTE
the electrical mains (~120V AC, ~60Hz). To shut down the product,
The power consumed
by the product is
disconnect the power supply cord (E) from the electrical mains.
nominally 30W.
4